EMSL order: NYC Law Dept. Office Equipment Air Sampling

Machine-extracted title · confidence 33%

EMSL analytical order for air sampling project related to NYC Law Dept. office equipment.

NYC-WTC_000449855
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document EMSL AMALVTICAL PAGE 01/01 01/28/2003 13:49 18568583551

EMSL Analytical, Inc. 107 Haddon .\vc., Wesmiont, NJ 08108

OrderID:040300858 Atto; Nitin Dave Customer ID; TRCESl IRC En vironmental Consultants Customer PC; 134 West 29'^ Street Received; 1/21/03 9:40 AM Penthouse New York, NY 10001 Fax: 212-221-7822 EMSL Order; 040300858 Project: #350S2-0000-00016/NYC LAW DEPT.- EMSL Project ID: OFFICE EQUIP. SIM. AIR SAMPLING ReponDate: 1/24/03 Date Analyzed: 1/22-23/03

Silica, Crystalline Analysis Performed X-Ray Diffraction (XRD) NIOSH Method 7500, Issue 3,1/15/98

Jte^pirable Dust Airborne Silica Sample Sample Silica Silica % Analytical Sample ID Identification Particle Vol Weight Cone. Weight Cone, Silica Sensitivity ID (1) (mg) (mg/tn’) (nig) (mg/m’) (nig/n?j

NA011803SILOSHA401 FIELD BLANK Quartz 0 0.035 N/A <0.0045 N/A N/A N/A 040300858-0001 NAC11S03S1LOSHA402 NAZAR Quartz 1166 0.114 0.0978 0.0080 0.0069 7.0 0.0039 ! 040300858-0002 AGAHAN NA011803SILOSHA403 MIKHAIL Quartz 1166 0.016 0.0137 0.0100 0.0086 62.5 0.0039 040300858-0003 SHINDELMAN Lab Blank Quartz 0 <0.002 N/A <0.0045 N/A N/A N/A Silica Standard 0.050Q Quartz 0 N/A N/A 0.047 N/A N/A N/A

Notes: I. Bulk sample not submitted with sample set. 2. Discernable field blank submitted with sample set. 3. Results are not field blank corrected. Disclaimer: The laboratory can only verify the concentration of silica on the filter and not the final concentration due to data obtained by non-laboratory persoiuiel. In the absence of a bulk dust sample, neither the specific forms of crystalline silica nor the interfering species can he fully determined. Hence, the amount for each phase, if anticipated, will be analyzed based on primary, secondary, and/or tertiary peak data with comparison to calibration curves of known standards. It should be noted that air samples are meant for only quantifying silica (or a mineral phase) which must first be identified from a bulk dust sample. “<" means less than tlie stated value. The lowest reportable value is equivalent to the Analytical Sensitivity that is calculated from the lowest reproducible amount of specific mineral detectable by the moment

Anant Satnudra, Ph.D. .1 /talyst Stephen Siegel, CUi- Lab Manager Or other approved signatory

AIHA Accredited - Laboratory’ JJ) #100}94 Page 1 of 1

CITY_21MC1OO_OO7139717

NYC-WTC_000449855

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449855Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000445229

EMSL order for air sampling project related to NYC Law Department equipment.

Similar indexed content

NYC-WTC_000428139

X-ray diffraction silica analysis performed under EMSL order 040305286 for NYC DEP project.

Similar indexed content

Compare copies and versions →