NYC-WTC_000428324
Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).
74 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.
NYC-WTC_000449648–000449764OCR status: ok · source: pdftotext
Z ■< Z ■<
o Ambient Air Monitoring Program Section No. 12 o co g Quality Assurance Project Plan Revision No.: 0 o 130 Liberty Street - NY, NY Date: August 2005 I Lower Manliattan Development Corporation “0 c o Page 73 of 116 o CT o o' CD "0 o ro 03 Table 12-1. Summary of Media, Preservation, and Holding Time Requirements Estimated Preservation Maximum Holding O o Analytical Parameter Analytical Method Media o Sample Volume Requirements Time c Metals SW-846 Method 6020A 1440 m" (1000 L/min 8” X 10” quartz fiber Stored in protective 180 days to analysis 3 o for 24 hours) filter envelope in desiccators 3
at temperature of 67 + 5°F and relative humidity of 33 + 5% until analysis Total Mercury EPA method 324, 0.576 m^ (0.4 L/min for 2 small iodated carbon None 28 days to analysis modified 24 hours) traps in series Asbestos NIOSH Method 7402 2.88 m^ (6 L/min for 25mm diameter cassette None None minimum of 8 hours) with 0.45 pm pore size, mixed cellulose ester filter Silica-Respirable NIOSH Method 7500 1.0 m’ SKC aluminum cyclone; None None (2.0-2.1 L/min for 8 37 mm diameter hours) cassette with 5.0 pm pore size, polyvinyl chloride filter Particulate PMio 40 CFR Part 50, 24.05 m’ 47 mm Teflon filters None None Appendix J (16.7 L/min for 24 hours) Particulate lAL s 40 CFR Part 50, 24.05 m^ 47 mm Teflon filters None None Appendix L (16.7 L/min for 24 hours) Dioxins/Furans EPA Method TO-9A 288 m^ (200 L/min for Quartz fiber filter and Cool to 4°C 30 days to extraction; 45 24 hours) PUF cartridge days from extraction to analysis o PCBs SW-846 Method 8082 7.2 m^ (5 L/min for 24 PUF cartridge Cool to 4°C; keep in 14 days to extraction; 40 H K hours) dark days from extraction to I analysis to
O s PAHs SW-846 Method 8270C 288 111 ' (200 L/min for 24 hours) Quai tz fiber filter, PUF/XAD-2 sandwich Cool to 4°C; keep in dark 14 days to extraction; 40 days from extraction to o cartridge analysis o I o o co to co L2005-346 Rev. 1 co tn tn
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000428324
Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).
74 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441561
Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.
76 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427221
Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.
74 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444248
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.
75 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447891
QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.
73 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447031
QA plan document for ambient air monitoring program for Liberty Street deconstruction.
73 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449908
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.
73 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448520
Quality assurance plan for ambient air monitoring during deconstruction at Liberty Street.
73 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443239
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.
73 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451508
Quality assurance plan for ambient air monitoring at the Liberty Street deconstruction site, Sep 2005.
73 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421711
Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.
74 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426556
Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.
72 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000427221
Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000428324
Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448520
Quality assurance plan for ambient air monitoring during deconstruction at Liberty Street.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444248
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443239
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449908
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).
Similar indexed content
Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.
Similar indexed content
Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.
Similar indexed content
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.
Similar indexed content
QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.
Similar indexed content