RJ IjceGroup, Inc. 350 Hochberg Road, Monroeville, PA 15146 Phone: (724) 325-1776 Fax: (724) 733-1799

Final Laboratory Report TEM Air Analysis RJ Lee Group, Inc. Report Date: 4/8/2005 350 Hochberg Road Sample Receipt Date: 4/8/2005 Monroeville, PA 15146 RJ Lee Group Job No.: ATII411066-502 USA Samples Received: 9 Method: Federal Register, 40 CFR, Part 763, October 30, 1987 Building: 4 Albany

Concentration

Date-Time Collected Filter Area Asbestos Analytical RJLG Sample Sample Start Area Volume Analyzed Structures Sensitivity Number Type Stop ■Sub Location I Comments- (mrr?) (liter) (mirf) Chry Amph (S/mrrf) (S/cc)

5251218.HT Area 4/7/2005 - 07:43:00 (East) - 8th floor. Near Elevator 385 2487.93 0.18044 0 0 <5.5 <0.001 4/7./2005 - 15:05:18 Shafts. "5.5 oool

5251219.HT Area 4/7/2005 - 07:45:00 (West) - 8th floor. Below Roof 385 2594.59 0.18044 0 0 <5.5 <0.001 4/7/2005 - 15:06:38 Abatement on 9th Floor. "5.5 (LOOT

5251220.HT Field 4/7/2005 - 07:45:00 (West) - 8th floor. Below Roof 385 0.000 0.18044 0 0 5.5 N/A Blank 4/7/2005 - 07:45:00 Abatement on 9th Floor. Field '5.5 'N/A Blank.

5251221.HT Area 4/7/2005 - 07:56:00 (SouthEast) - Remote Waste Decon 385 2730.00 0.18044 0 0 <5.5 <0.001 4/7/2005 - 14:56:00 Clean Room. 9th Floor. (Phase IV). ”5.5 (LOOT

5251222.HT Area 4/7/2005 - 07:57:00 (SouthEast) - Remote Personal 385 2736.50 0.18044 0 0 <5.5 <0.001 4/7/2005 - 14:58:00 Decon Clean Room. 9th Floor. "5.5 oool (Phase rV).

5251223.HT Area 4/7/2005 - 07:53:00 (East) - 9th floor. Airlock Near A 385 2797.38 0.18044 0 0 <5.5 <0.001 4/7/2005 - 15:03:22 Stairwell. 5.5 0.00 f

5251224.HT Area 4/7/2005 -08:01:00 (Northwest) - OSWA. 9th Floor. 385 2299.45 0.18044 0 0 <5.5 <0.001 4/7/2005 - 14:59:05 "5.5 oool

Notes: 1. Volumes provided by Deutsche Bank were used to calculate analytical results and sensitivities. 2. “<” indicates results less than analytical sensitivity. “—” indicates that sample was not analyzed. 3. Sample(s) for this project were analyzed at our: Monroeville, PA (NVLAP #101208-0, NY ELAP #10844) facility. 4. If RJ Lee Group, Inc. did not collect tire samples analyzed, tire verifiability of the laboratoiy's results ai e limited to tlie reported values. 5. Abbreviations: N/A-Not Applicable, Chry-Chrysotile Asbestos, Amph-Amphibole Asbestos, S-Structures. 6. Samples will be held for 90 days and then disposed of per Federal regulations. 7. These results are submitted pursuant to RJ Lee Group’s current terms and conditions of sale, including the company’s standard warranty and limitation of liability provisions. No responsibility or liability is assumed for tlie maimer in which tliese results are used or interpreted.

Page 1 of 3

CITY_21MC100_0 03226995

NYC-WTC_000449157

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449157Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000233155

Final air analysis report detailing testing methods and results conducted by RJ [name] Inc. for building environmental assessment.

Similar indexed content

NYC-WTC_000448500

Final air analysis report detailing testing methods and results conducted by RJ [name] Inc. for building environmental assessment.

Similar indexed content

NYC-WTC_000450872

Final air analysis report detailing testing methods and results conducted by RJ [name] Inc. for building environmental assessment.

Similar indexed content

NYC-WTC_000441856

Final TEM air analysis laboratory report dated 04/10/2005.

Similar indexed content

Compare copies and versions →