Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 73 of 124

PCDDs and PAHs

Field spikes are clean media used for sampling and pre-spiked with ^^Cn-labeled compounds (similar to the target analytes) and used to evaluate overall accuracy. The media will be spiked in the laboratory, sent out to the field with all sample media, and returned to the laboratory for analysis.

Total Mercury

In addition, during the background phase of the program, the accuracy and precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the accuracy and precision of the method under actual field sampling condition. Following the background phase, one field spike will be performed every other week.

10.3.5 Breakthrough Checks

Separate analyses of both front and back half portions of carbon traps for mercury will be performed during the background phase to allow for an assessment of analyte breakthrough. The breakthrough assessment will be performed on all stations during the background phase. Breakthrough on the back half of the trap must be < 2% of the front half of the trap or < 5 ng per trap. If breakthrough criteria are consistently met during the background phase, subsequent measurement will be performed with the front and back halves of the carbon traps combined for analyses.

10.3.6 Media Certification Checks

Media for all analyses collected a on time-integrated basis will be certified clean from the laboratories. The certifications will be performed as batch checks and results will be stored in the project files.

CITY_21MC100_0 03238595

NYC-WTC_000448593

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000448593Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →