Chain of custody, Greenwich/Thames Air Monitoring Plan

Machine-extracted title · confidence 50%

Title/approval sheet for Environmental Community Air Monitoring Program and Greenwich/Thames Plan.

NYC-WTC_000448085–000448218
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

packed upright in rigid containers to avoid any unnecessary sample disturbance. Shipping containers will be secured for shipment to the laboratory. If an authorized laboratory courier does not pickup the samples from the project site, custody seals will be attached to the front right and back left of the cooler and covered with clear plastic tape after being signed by field personnel. An example of a cooler custody seal is provided in Figure 12-3. Subsequently, the cooler will be strapped shut with strapping tape in at least two locations.

• If the samples are sent by common carrier, the air bill will be used. Air bills will be retained by the laboratory as part of the permanent documentation. Commercial carriers are not required to sign off on the custody forms since the custody forms will be sealed inside the sample cooler and the custody seals will remain intact.

• Samples remain in the custody of the sampler until transfer of custody is completed. This consists of delivery of samples to the laboratory sample custodian, and signature of the laboratory sample custodian on the chain-of- custody document as receiving the samples and signature of sampler as relinquishing samples.

12.1.2 Laboratory Sample Custody

Samples will be received and logged in by a designated sample custodian or his/her designee. Upon sample receipt, the sample custodian will

• Examine the shipping containers to verify that the custody tape is intact, • Examine all sample containers for damage, • Determine if the temperature required for the requested testing program has been maintained during shipment and document the temperature on the chain-of- custody or sample login records, • Compare samples received against those listed on the chain-of-custody, • Verify that sample holding times have not been exceeded, • Examine all shipping records for accuracy and completeness • Sign and date the chain-of-custody immediately (if shipment is accepted) and attach the air bill, • Note any problems associated with the coolers and/or samples on the cooler receipt form and notify the Laboratory Project Manager, who will be responsible for contacting the AIRTEK Project QA Officer, • Attach laboratory sample container labels with unique laboratory identification and test, and • Place the samples in the proper laboratory storage.

Following receipt, samples will be logged in according to the following procedure: • The samples will be entered into the laboratory tracking system. At a minimum.

79

CITY_21MC100_011979819

NYC-WTC_000448163

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000448163Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

Compare copies and versions →