NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Streel/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
packed upright in rigid containers to avoid any unnecessary sample disturbance.
Shipping containers will be secured for shipment to the laboratory. If an
authorized laboratory courier does not pickup the samples from the project site,
custody seals will be attached to the front right and back left of the cooler and
covered with clear plastic tape after being signed by field personnel. An example
of a cooler custody seal is provided in Figure 12-3. Subsequently, the cooler will
be strapped shut with strapping tape in at least two locations.
• If the samples are sent by common carrier, the air bill will be used. Air bills will
be retained by the laboratory as part of the permanent documentation.
Commercial carriers are not required to sign off on the custody forms since the
custody forms will be sealed inside the sample cooler and the custody seals will
remain intact.
• Samples remain in the custody of the sampler until transfer of custody is
completed. This consists of delivery of samples to the laboratory sample
custodian, and signature of the laboratory sample custodian on the chain-of-
custody document as receiving the samples and signature of sampler as
relinquishing samples.
12.1.2 Laboratory Sample Custody
Samples will be received and logged in by a designated sample custodian or his/her
designee. Upon sample receipt, the sample custodian will
• Examine the shipping containers to verify that the custody tape is intact,
• Examine all sample containers for damage,
• Determine if the temperature required for the requested testing program has been
maintained during shipment and document the temperature on the chain-of-
custody or sample login records,
• Compare samples received against those listed on the chain-of-custody,
• Verify that sample holding times have not been exceeded,
• Examine all shipping records for accuracy and completeness
• Sign and date the chain-of-custody immediately (if shipment is accepted) and
attach the air bill,
• Note any problems associated with the coolers and/or samples on the cooler
receipt form and notify the Laboratory Project Manager, who will be responsible
for contacting the AIRTEK Project QA Officer, • Attach laboratory sample
container labels with unique laboratory identification and test, and
• Place the samples in the proper laboratory storage.
Following receipt, samples will be logged in according to the following procedure:
• The samples will be entered into the laboratory tracking system. At a minimum.