Chain of custody, Greenwich/Thames Air Monitoring Plan

Machine-extracted title · confidence 50%

Title/approval sheet for Environmental Community Air Monitoring Program and Greenwich/Thames Plan.

NYC-WTC_000448085–000448218
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

be performed during the background phase to allow for an assessment of analyte breakthrough. The breakthrough assessment will be performed on all stations during the background phase. Breakthrough on the back half of the trap must be < 2% of the front half of the trap or < 5 ng per trap. If breakthrough criteria are consistently met during the background phase, subsequent measurement will be performed with the front and back halves of the carbon traps combined for analyses.

10.3.6 Media Certification Checks

Media for all analyses collected a on time-integrated basis will be certified clean from the laboratories. The certifications will be performed as batch checks and results will be stored in the project files.

11.0 ANALYTICAL REQUIREMENTS

11.1 Analytical Methods

This section of the QAPP describes the analytical techniques that will be used by the fixed laboratories to generate definitive data for the project. It documents the fixed laboratory analytical methods that will be used to meet measurement performance criteria and achieve the project-required quantitation limits for all contaminants of concern in the specific matrices as identified on Tables 8-la-c.

11.1.1 Fixed Laboratory Analytical Methods and SOPs

Table 11-1 details the analytical methods that will be used in this investigation

11.1.2 Fixed Laboratory Analytical Method/SOP Modifications

The cited methods will be followed as written with the exceptions summarized below. These modifications do not adversely affect the quality or usability of the data as sufficient quality control analyses will be performed demonstrating adequate method performance with these modifications.

11.1.2.1 PAH Extraction by EPA Method TO-13A and Analysis by SW-846 Method 827()C

The analysis of PAHs using SW-846 Method 8270C will be modified to include the use of selective ion monitoring (SIM). Modifications to the sample preparation procedure in EPA Method TO-13 are listed below.

• The XAD-2 resin is dried in a fume hood for 16 hours instead of dried in a vacuum oven with ultra-pure nitrogen for 2-4 hours. • The laboratory uses methylene chloride-rinsed aluminum foil instead of hexane- rinsed aluminum foil.

71

CITY_21MC100_011979811

NYC-WTC_000448155

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000448155Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.