Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
Cooler temperature blanks consist of a sample container filled with non-preserved water
(potable or distilled) and are included in all coolers which contain samples which require
temperature preservation (PAHs, PCBs, PCDDs/PCDFs). The laboratory uses these
temperature blanks to ensure that proper preservation of the samples has been maintained
during sample shipment. The temperature of these blanks must be 4 "C +2° to
demonstrate that proper preservation has been maintained. The laboratory records the
results of the temperature blanks on the chain-of custody or sample login form
immediately upon receipt of the samples at the laboratory, prior to inventory and
refrigeration.
10.3.3 Field Duplicates
Field duplicates will be collocated samples. Collocated samples are two samples
collected next to each other in the same vertical position. Collocated samples require two
separate sample collections at the same location. Field duplicates will be used to assess
the sampling and analytical reproducibility. With the exception of total mercury, field
duplicates will be submitted at a frequency of once per week per analytical parameter.
For total mercury, field duplicates and field spikes will be alternated on a weekly basis.
Field duplicates for waste characterization will be duplicate subsamples. Duplicate
subsamples are an additional aliquot of the same sample submitted for the same
parameters as the original sample and will be used for aqueous and solid matrices.
Duplicate subsamples will be collected by alternately filling sample containers from the
source being sampled. Field duplicates will be used to assess the sampling and analytical
reproducibility. Field duplicates will be submitted at a frequency of once per 10 samples
per matrix per analytical parameter (with the exception of corrosivity and ignitability).
10.3.4 Field Spikes
PCDDs and PAHs Field spikes are clean media used for sampling and pre-spiked with
i3Ci2-labeled compounds (similar to the target analytes) and used to evaluate overall
accuracy. The media will be spiked in the laboratory, sent out to the field with all sample
media, and returned to the laboratory for analysis.
Total Mercury In addition, during the background phase of the program, the accuracy
and precision of the mercury sampling and analysis method will be tested. Ambient air
samples will be collected at one location using a series of four carbon traps prespiked (50
ng/trap) with mercury. These samples will provide data on the accuracy and precision of
the method under actual field sampling condition. Following the background phase, one
field spike will be performed every other week.
10.3.5 Breakthrough Checks
Separate analyses of both front and back half portions of carbon traps for mercury will
70
CITY_21MC100_011979810
NYC-WTC_000448154