Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 46%

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

NYC-WTC_000447891–000448022
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 13 Quality Assurance Project Plan Revision No.: 0 1301 I bcriy Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 94 of 124

Metals (TSP Filters)

Table 13-3a summarizes the calibration procedures associated with the high volume samplers used to collect metals (TSP) samples.

Table 13-3a. Calibration Requirements for High Volume Samplers Equipment Activity Acceptance Corrective Action Criteria High volume sampler Initial Calibration: NA NA Multipoint calibration performed before first use, quarterly thereafter, after relocation to new site, or after repairs which may affect calibration Single point flow check Within ±20% of the Service high volume at normal operating flow flow rate indicated by sampler and perform rate on weekly basis the high volume a new multi-point sampler calibration. Orifice Transfer Annual calibration by NA NA Standard manufacturer.^"^’ Calibration records maintained and tracked by Quality Assurance Officer and Field Sampling Coordinator.

Meteorological Monitoring

Calibration of the meteorological monitor will be done quarterly for the wind direction and wind speed. A yearly calibration will be performed for the voltages.

Mercury (Gaseous) Using an Ohio Lumex RA915+ Mercury Analyzer

Table 13-3b summarizes the calibration procedures associated with the mercury (gaseous) analysis using the Ohio Lumex RA915+ Mercury Analyzer.

CITY_21MC100_0 03219930

NYC-WTC_000447985

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447985Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →