NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 132 pages

Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 46%

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

NYC-WTC_000447891–000448022
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 8 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 56 of 124

In general, representativeness in the field will be maximized by following the reference sampling methodologies, proper sample preservation procedures, utilizing experienced/trained sampling crews, and conducting field audits.

Measures to Ensure Representativeness of Laboratory Data

Representativeness in the laboratory is ensured by using the proper analytical procedures, appropriate methods, and meeting sample holding times. Following the detailed requirements outlined in the EPA and NIOSH methods will maximize the representativeness of the laboratory data.

8.2.4 Comparability

Comparability is a qualitative parameter that expresses the confidence with which one data set can be compared to another.

Measures to Ensure Field Comparability

Comparability is dependent upon the proper design of the sampling program and will be satisfied by ensuring that the QAPP is followed, sampling and analytical methodologies are followed, and that proper sampling and preservation techniques are used.

Measures to Ensure Laboratory Comparability

Comparability is dependent on the use of the selected EPA and NIOSH methods that are appropriate for producing data that may be compared to the project Action Limits and the reporting of data in standardized units.

8.2.5 Sensitivity

Sensitivity is the ability of the instrument or method to detect the contaminants of concern at the level of interest.

Quantitation Limits

Table 8-1 outlines the required quantitation limits for each matrix, each analytical parameter and each analyte. These quantitation limits are significantly below the project Action Limits. In almost all cases, EPA or NIOSH methodologies were selected with specific requirements or modifications to achieve quantitation limits that are significantly below the project Action Limits. The laboratories selected will, at a minimum, meet the project quantitation limits included in Table 8-1.

Laboratories will need to adjust all quantitation limits based on dilutions, sample volumes, extract/digestate volumes, and cleanup procedures. In all cases, the adjusted quantitation limit (or sample quantitation limit) must be below the project Action Limit. In establishing the

CITY_21MC100_003219892

NYC-WTC_000447947

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447947Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →