Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 46%

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

NYC-WTC_000447891–000448022
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 8 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 55 of 124

• Will identify the phases of silica potentially present in the air • Will show interferences that may require the use of secondary and/or tertiary peaks for silica phase quantitation

8.2.3 Representativeness

Representativeness is a qualitative parameter which expresses the degree to which the data and sampling design accurately and precisely represent a characteristic of a population, parameter variations at a sampling point, a process condition, or an environmental condition within a defined spatial and/or temporal boundary. Representativeness is a qualitative parameter which is dependent upon the proper design of the sampling program and the laboratory quality control program.

The air monitoring network has been designed so as to capture air emissions if any at all potential release points during building deconstruction. This includes monitoring stations at all major compass points at both ground and elevated levels around the building perimeter. These perimeter locations as a result are representative of locations both upwind and downwind of the deconstruction site based upon historical meteorological data available for the New York Metropolitan area. In addition four (4) monitoring stations will be situated out of the immediate vicinity of the deconstruction site on roof tops of buildings again coincident with prevailing winds in the site vicinity. This twelve (12) station network should provide adequate spatial orientation around the deconstmction site so as to capture any dust releases during the deconstruction project. In fact, the scaffolding locations represent “floating” stations which will move coincident with the building deconstruction as it moves from elevation to ground level. The coverage provided by these twelve (12) stations in contemporaneous operation in concert with site specific meteorology will provide sufficient data to examine the source(s) of any exceedances that may occur during the term of the project. This analyses includes contributions from regional or background air quality, effects of the deconstruction activities as well as contributions attributable to activities on site or off site upwind or downwind of the 130 Liberty Street property itself.

Measures to Ensure Representativeness of Field Data

Representativeness is dependent upon the proper design of the sampling program and will be satisfied by ensuring that the Ambient Air Monitoring Program, referenced sampling methodologies, and required QC procedures are followed and that proper sampling, sample handling, and sample preservation techniques are used. Refer to Section 10.1 of the QAPP for the sampling design which will provide representative data over the site. Representativeness may also be assessed by the use of field duplicate samples. By definition, field duplicate samples are collected so they are equally representative of a given point in space and time. In this way, they provide both precision and representativeness information. As stated previously, field duplicate samples will generally be collected at a frequency of one per week per analytical parameter.

CITY_21MC100_003219891

NYC-WTC_000447946

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447946Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →