NYC 9/11 Public Portal Document
ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 2, dated 15 August 1994 - Page 3 of 15
EQUIPMENT:
10. Acetone flash vaporization system for clearing filters on glass slides (see ref. [5] for specifications or see manufacturer's instructions for equivalent devices). 11. Micropipets or syringes, 5-pL and 100- to 500-pL. 12. Microscope, positive phase (dark) contrast, with green or blue filter, adjustable field iris, 8 to 10X eyepiece, and 40 to 45X phase objective (total magnification ca. 400X); numerical aperture = 0.65 to 0.75. 13. Graticule, Walton-Beckett type with lOO-pm diameter circular field (area = 0.00785 mm at the specimen plane (Type G-22). Available from Optometries USA, P.O. Box 699, Ayer, MA 01432 [phone (508)-772-1700], and McCrone Accessories and Components, 850 Pasquinelli Drive, Westmont, IL 60559 [phone (312) 887-7100]. NOTE: The graticule is custom-made for each microscope, (see APPENDIX A for the custom-ordering procedure). 14. HSE/NPL phase contrast test slide, Mark II. Available from Optometries USA (address above). 15. Telescope, ocular phase-ring centering. 16. Stage micrometer (0.01-mm divisions).
SPECIAL PRECAUTIONS: Acetone is extremely flammable. Take precautions not to ignite it. Heating of acetone in volumes greater than 1 mL must be done in a ventilated laboratory fume hood using a flameless, spark-free heat source.
SAMPLING:
1. Calibrate each personal sampling pump with a representative sampler in line. 2. To reduce contamination and to hold the cassette tightly together, seal the crease between the cassette base and the cowl with a shrink band or light colored adhesive tape. For personal sampling, fasten the (uncapped) open-face cassette to the worker's lapel. The open face should be oriented downward. NOTE: The cowl should be electrically grounded during area sampling, especially under conditions of low relative humidity. Use a hose clamp to secure one end of the wire (Equipment, Item 3) to the monitor's cowl. Connect the other end to an earth ground (i.e., cold water pipe). 3. Submit at least two field blanks (or 10% of the total samples, whichever is greater) for each set of samples. Handle field blanks in a manner representative of actual handling of associated samples in the set. Open field blank cassettes at the same time as other cassettes just prior to sampling. Store top covers and cassettes in a clean area (e.g., a closed bag or box) with the top covers from the sampling cassettes during the sampling period. 4. Sample at 0.5 L/min or greater [6]. Adjust sampling flow rate, Q (Umin), and time, t (min), to produce a fiber density, E, of 100 to 1300 fibers/mm (3.85-10* to 5-10® fibers per 25-mm filter with effective collection area A 385 mm^) for optimum accuracy. These variables are related
NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94
CITY_21MC100_011980878
NYC-WTC_000447381
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000433590
PCM analysis of asbestos and other fibers with reference thresholds.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434430
PCM/NIOSH/ACGIH reference for asbestos fiber measurement; method 7400 with detection limits.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000440917
Asbestos and other fibers results using PCM/TEM method; method details and sampling data.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451078
Asbestos and other fibers by PCM/TEM method 7400; evaluation guidelines included.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450586
PCM asbestos method overview and regulatory limits for fibers.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452274
Laboratory report detailing asbestos fiber measurements by PCM/TEM.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442815
Fiber analysis method overview and PCM/NIOSH/OSHA references for asbestos.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435596
Lab report describing asbestos and other fibers by PCM with guidelines and CAS numbers.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446427
Laboratory method overview for asbestos and other fibers by PCM; regulatory references included.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445725
Summary of PCM/analytical methods for asbestos and related fibers (7400).
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450084
Asbestos and other fibers methodology and evaluation (PCM/AHERA) with reference to 7400 method.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441031
Documentation of asbestos and other fibers identification methods and reporting framework using PCM/TEM.
17 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000435596
Lab report describing asbestos and other fibers by PCM with guidelines and CAS numbers.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434430
PCM/NIOSH/ACGIH reference for asbestos fiber measurement; method 7400 with detection limits.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433590
PCM analysis of asbestos and other fibers with reference thresholds.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442815
Fiber analysis method overview and PCM/NIOSH/OSHA references for asbestos.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000440917
Asbestos and other fibers results using PCM/TEM method; method details and sampling data.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452274
Laboratory report detailing asbestos fiber measurements by PCM/TEM.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000433590
PCM analysis of asbestos and other fibers with reference thresholds.
Similar indexed content
NYC-WTC_000434430
PCM/NIOSH/ACGIH reference for asbestos fiber measurement; method 7400 with detection limits.
Similar indexed content
NYC-WTC_000440917
Asbestos and other fibers results using PCM/TEM method; method details and sampling data.
Similar indexed content
NYC-WTC_000451078
Asbestos and other fibers by PCM/TEM method 7400; evaluation guidelines included.
Similar indexed content
NYC-WTC_000450586
PCM asbestos method overview and regulatory limits for fibers.
Similar indexed content