NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Asbestos by PCM/TEM, 7400 method, general data

Machine-extracted title · confidence 46%

Asbestos and other fibers results using PCM/TEM method; method details and sampling data.

NYC-WTC_000440917–000440931
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ASBESTOS and OTHER FIBERS by PCM: METHOD 7400, Issue 2, dated 15 August 1994 - Page 3 of 15

EQUIPMENT:

10. Acetone flash vaporization system for clearing filters on glass slides (see ref. [5] for specifications or see manufacturer's instructions for equivalent devices). 11. Micropipets or syringes, 5-pL and 100- to 500-pL. 12. Microscope, positive phase (dark) contrast, with green or blue filter, adjustable field iris, 8 to 10X eyepiece, and 40 to 45X phase objective (total magnification ca. 400X); numerical aperture = 0.65 to 0.75. 13. Graticule, Walton-Beckett type with lOO-pm diameter circular field (area = 0.00785 mm at the specimen plane (Type G-22). Available from Optometries USA, P.O. Box 699, Ayer, MA 01432 [phone (508)-772-1700], and McCrone Accessories and Components, 850 Pasquinelli Drive, Westmont, IL 60559 [phone (312) 887-7100]. NOTE: The graticule is custom-made for each microscope, (see APPENDIX A for the custom-ordering procedure). 14. HSE/NPL phase contrast test slide, Mark II. Available from Optometries USA (address above). 15. Telescope, ocular phase-ring centering. 16. Stage micrometer (0.01-mm divisions).

SPECIAL PRECAUTIONS: Acetone is extremely flammable. Take precautions not to ignite it. Heating of acetone in volumes greater than 1 mL must be done in a ventilated laboratory fume hood using a flameless, spark-free heat source.

SAMPLING:

1. Calibrate each personal sampling pump with a representative sampler in line. 2. To reduce contamination and to hold the cassette tightly together, seal the crease between the cassette base and the cowl with a shrink band or light colored adhesive tape. For personal sampling, fasten the (uncapped) open-face cassette to the worker's lapel. The open face should be oriented downward. NOTE: The cowl should be electrically grounded during area sampling, especially under conditions of low relative humidity. Use a hose clamp to secure one end of the wire (Equipment, Item 3) to the monitor's cowl. Connect the other end to an earth ground (i.e., cold water pipe). 3. Submit at least two field blanks (or 10% of the total samples, whichever is greater) for each set of samples. Handle field blanks in a manner representative of actual handling of associated samples in the set. Open field blank cassettes at the same time as other cassettes just prior to sampling. Store top covers and cassettes in a clean area (e.g., a closed bag or box) with the top covers from the sampling cassettes during the sampling period. 4. Sample at 0.5 L/min or greater [6]. Adjust sampling flow rate, Q (Umin), and time, t (min), to produce a fiber density, E, of 100 to 1300 fibers/mm (3.85-10* to 5-10® fibers per 25-mm filter with effective collection area A 385 mm^) for optimum accuracy. These variables are related

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94

CITY_21MC100_003220882

NYC-WTC_000440919

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000440919Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447379

PCM asbestos and related fiber analysis methodology overview with sampling details.

Similar indexed content

Compare copies and versions →