NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

Chain-of-custody for air monitoring plans, Greenwich/Thames, Nov 2005

Machine-extracted title · confidence 42%

Chain-of-custody form for Environmental Community Air Monitoring Program plans at Greenwich Street and Thames Street, dated November 4, 2005.

NYC-WTC_000443742–000443870
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Slreet/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

• Conformance to the field methodologies proposed in the QAPP, • Conformance to the EPA and NIOSH methods provided in the QAPP, • Adherence to proposed sampling strategy, • Presence of elevated detection limits due to matrix interferences present in background ambient air or contaminants present at high concentrations, • Presence of analytes not expected to be present, • Conformance to validation protocols included in the QAPP for both field and laboratory data, • Unusable data sets (qualified as “R”) based on the data validation results, • Data sets identified as usable for limited purposes (qualified as “J”) based on the data validation results, • Effect of qualifiers applied as a result of data validation on the ability to achieve the project objectives, • Status of all issues requiring corrective action, as presented in the QA reports to management, • Effect of nonconformance (procedures or requirements) on project objectives, • Adequacy of the data as a whole in meeting the project objectives, • Identification of any remaining data gaps and need to reevaluate data needs, • Examination of site-specific and regional meteorological data to identify the source(s) of the elevated ambient concentrations. Is the elevated concentration likely attributable to activities at 133-135 Greenwich Street and 21-23 Thames Street, regional background, site-specific influences or none of the above, and • Examine collateral data collected at the site (e.g., elevated metals concentrations should coincide with elevated particulate concentrations at the same site).

Every attempt will be made to eliminate any sources of sampling and analytical error as early as possible in the program. An ongoing data assessment program throughout the program will also assist in the early detection and correction of problems, thereby ensuring that project objectives are met. Reconciliation with the project objectives will have been considered to have been met if the measurement performance criteria from Section 8.0 are met. If the data usability indicates that the project quality objectives in Section 8.0 have not been met, then the project management team will meet to determine any additional work to be performed.

17.0 REPORTING, DOCUMENTS, AND RECORDS

QA reports will be submitted to the AIRTEK Project Manager to ensure that any problems identified during the sampling and analysis programs are investigated and the proper corrective measures taken in response. The QA reports may include:

• All results of field and laboratory audits, • Problems noted during data validation and assessment, and

120

CITY_21MC100_007120972

NYC-WTC_000443861

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000443861Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000440780

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →