TRC Customer-Focused Solutions During the same March 20, 2006 sampling period a silica concentration of 2ug/M3 was measured at Station #10 along the site perimeter and immediately west of the Fire House. Silica concentrations measured at all ten other stations in the 130 Eiberty Street network were non­ detected (< lug/M3) for the March 20, 2006 sampling period. It should be noted that silica represented 37 and 39% of the total particulate measured by NIOSH Method 7500 at Stations #5 and #10, respectively. This suggests a common source of the particulate measured at the two locations albeit Station #5 appears closer to the dust source than Station #10 situated further downwind.

Review of the 130 Eiberty Street PM 10 data for the March 20 2006 sampling period indicates that the highest concentration as a 24 hour average was observed at Station #5 with a concentration of 32 ug/M3. Note the NIOSH 7500 Respirable Dust concentration of 34 ug/M3 at station #5 confirms this result. The 2"** highest concentration (26 ug/M3) was observed at Station #10. These data again support the prior visual observations regarding an off-site dust plume moving towards the Fire House on the late morning of March 20, 2006. Review of these data files indicates a marked spike in measured PM 10 concentrations at Station #5 coincident with the prior visual observations including alO minute average concentration of 250 ug/M3 at 1230pm.

Based on this inforaiation, TRC believes that the one sample exceedance for silica recorded for Station #5 (10-10 Firehouse) on March 20, 2006 is attributable to an off-site dust source and not associated with work at 130 Eiberty Street.

TRC concluded its evaluation of the lab data and verified exceedance at approximately 12:00. TRC Notified the EPA via telephone at approximately 12:30. Work Stopped on site approximately 14:00.

Edward A. Gerdts, CIH, CSP Vice President TRC Environmental Corporation 1430 Broadway - 10th Floor New York, New York 10018

Phone: (212) 221-7822 x 111 Fax: (212) 221-7840 Mobile : (917) 549-6197

Date: March 24, 2006

CITY_21MC100_009194088

NYC-WTC_000442213

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000442213Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000428161

Summary of silica exceedance at Station 5, 3/20/2006, report to TRC.

Similar indexed content

Compare copies and versions →