NYC-WTC_000445521
Preliminary results for runoff sampling near WTC site (Sept 2001).
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Preliminary results for metals, PAHs, TSS from WTC-area runoff and ambient samples; coordination with agencies.
NYC-WTC_000440951–000440953OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
September 23, 2001 (10:31am) Preliminary Results Metals, PAHs, TSS New York City/ World Trade Center Sampling Activities Ambient Sampling <& Rector Street Runoff Resampling
EPA Personnel: Street Runoff - Stephen Hale, Erwin Smieszek, Towana Joseph Ambient Sampling - Warren McHose, Helen Grebe, Dick Coleates, Kathleen Savino
Sampling Date: September 20, 2001 Sampling Time: Afternoon - during rainstorms/ Samples arrived Edison 6-7:30 PM Location: Hudson River and East River Sample Matrix: Water Analytes , Laboratory: Region 2 Edison - Metals), TSS, PAHs, PCB congeners NYS DEC Coniracior (Axys) - PCB congeners, PA^Hs, Dio>;ins/Furans Contract (Raj Singhvi coordinating, Ambient sample asbestos NYSDOH/Wadworth (Dr. J. Webber), Runoff sample asbestos
Runoff Sampling: Samples of runoff from the location at the foot of Rector St. previously sam.pled on 09/14/01 during rain storm/street washdown. No washdown was being conducted during this sampling event, and flow from the discharge pipe was very low. The EPA Whaler supported the sampling.
Ambient Sampling: Ambient samples were collected from three locations in the Hudson River; directly west of Ground Zero, north of Ground Zero, south of Ground Zero. A reference (background) sample was collected near the George Washington Bridge. A sample was collected in the East River east of South Street Seaport. The EP.A Clean Waters supported the sampling.
HR-B ackground 40 50.210 N 073 57.384 W
HR-North WTC 40 43.427 N 074 01.272 W
HR-West WTC 40 42.903 N 074 01.332 W
HR-South WTC 40 42.133 N 074 01.417 W
ER-South St. 40 42.210 N 074 00.071 W
Preliminary Results:
Metals: Metals were analyzed in the Region 11 laboratory. No metals were detected at levels of concern. For most detected metals, concentrations were greatest in the background George Washington Bridge sample. Rector St, Runoff
CITY_21MC100_003223003
NYC-WTC_000440951
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000445521
Preliminary results for runoff sampling near WTC site (Sept 2001).
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443889
Preliminary results memo for EPA/NYS sampling near Rector Street and World Trade Center area, Sept 20-23, 2001.
15 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307580
Preliminary EPA/DEC findings for NYC/World Trade Center runoff and metals/PAHs.
15 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290030
Preliminary results: asbestos decrease, metals/PAHs changes, and TSS at WTC sites.
15 shared non-person entities · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407815
Fire department preliminary runoff and ambient sampling results for asbestos, metals, PAHs, and TSS near World Trade Center sites, Sept 2001.
15 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205222
EPA report on asbestos air sampling results at specific World Trade Center locations on September 23, 2001.
10 shared non-person entities · 1 shared topics · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360584
Preliminary metals, PAHs, TSS, PCBs and asbestos runoff/ambient sampling coordination among agencies.
7 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340008
September 23, 2001 preliminary metals/PAHs/TSS results from WTC sampling activities.
7 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000432199
Preliminary dewatering discharge sampling results; various contaminants and comparatives.
13 shared non-person entities · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275318
Preliminary results summary for NYC/World Trade Center sampling, with asbestos, metals, PAHs, and TSS findings.
6 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280388
Preliminary report of runoff-related sampling; metals, PAHs, TSS with EPA/NYS DEC contributions.
7 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339747
Preliminary metals/PAHs/TSS runoff sampling at World Trade Center and Rector Street; EPA/DEC coordination noted.
7 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000443889
Preliminary results memo for EPA/NYS sampling near Rector Street and World Trade Center area, Sept 20-23, 2001.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445521
Preliminary results for runoff sampling near WTC site (Sept 2001).
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280388
Preliminary report of runoff-related sampling; metals, PAHs, TSS with EPA/NYS DEC contributions.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339747
Preliminary metals/PAHs/TSS runoff sampling at World Trade Center and Rector Street; EPA/DEC coordination noted.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360584
Preliminary metals, PAHs, TSS, PCBs and asbestos runoff/ambient sampling coordination among agencies.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340008
September 23, 2001 preliminary metals/PAHs/TSS results from WTC sampling activities.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000445521
Preliminary results for runoff sampling near WTC site (Sept 2001).
Similar indexed content
NYC-WTC_000443889
Preliminary results memo for EPA/NYS sampling near Rector Street and World Trade Center area, Sept 20-23, 2001.
Similar indexed content
NYC-WTC_000290030
Preliminary results: asbestos decrease, metals/PAHs changes, and TSS at WTC sites.
Similar indexed content
Preliminary EPA/DEC findings for NYC/World Trade Center runoff and metals/PAHs.
Similar indexed content
NYC-WTC_000407815
Fire department preliminary runoff and ambient sampling results for asbestos, metals, PAHs, and TSS near World Trade Center sites, Sept 2001.
Similar indexed content