Ambient Air Monitoring Program Section No. 8 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 1, 2005 Lower Manhattan Development Corporation Page 51 of 124

Table 8-6. Measurement Performance Criteria Table - Mercury by CVAFS QC Sample or Activity Frequency Measurement Performance Criteria Corrective Action DQI Field Duplicates' 1/every other *RPD < 40 when positive results for both Assess laboratory precision, and/or Precision-Overall week samples are > 5x QL qualify data. *No situation where one result is detected at > 5x QL and other result is not detected Laboratory Control Sample 1/prep batch Percent recoveries 80-120% Determine cause of problem, Accuracy/Bias reanalyze, and/or qualify data. Metliod Blanks 1/prep batch Mercury must be < 15 ng per trap Reclean, reanalyze and/or qualify Accuracy/Bias- data. Contamination Calibration Blanks 1/10 samples Mercury must be < 50 pg Reclean, reanalyze and/or qualify Accuracy/Bias- data. Contamination Field Spikes' 4 spikes/ Percent recoveries 80-120%; %RSD < 30 Reanalyze and/or qualify data Accuracy/Bias and background phase in background phase Precision followed by 1 spike/every other week Duplicate Injections Every sample, RPDs must be < 10 when positive results Reanalyze and/or qualify data. Precision blank, QC for both injections are > 5x QL Triplicate Injections Every 10 samples % RSD <10 when positive results for all Reanalyze and/or qualify data. Precision injections are > 5x QL Standard Additions 1/10 samples Percent recoveries 85-115% Recalibrate, reanalyze, and/or Accuracy/Bias qualify data. Breakthrough Check 1/location during Back half trap results must be < 2% of Qualify data and/or change Accuracy/Bias background phase front half trap results or < 5ng per trap subsequent sampling volumes. Field/Trip Blanks 1/day Mercury must be < 15 ng per trap Reclean, reanalyze and/or qualify Accuracy/Bias- o data. Contamination H Media Cleaning Verification 1/batch Mercury must be < 15 ng per trap Reclean and retest media. Accuracy/Bias- to Check Contamination s O I—1 Data Completeness Check NA Field 80%, Laboratory 95% ^Collection of Field Duplicates and Field Spikes will be alternated on a weekly basis. NA Data Completeness

o o Reanalyze: refers to reanalysis of same digestate. I o

L2005-346 Rev. 1 co

NYC-WTC_000440591

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000440591Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000441561

Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

Compare copies and versions →