Ambient Air Monitoring Program Section No. 14 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 1, 2005 Lower Manhattan Development Corporation Page 112 of 124

format is provided in Attachment E. A spreadsheet will be generated using the EDDs to provide results of the target parameters compared to the Target Air Quality Eevels, 3x the Target Air Quality Eevels, and the USEPA Site-Specific Trigger Eevels. The laboratory will calculate all results using sample volumes provided by TRC.

A cumulative average will be generated after the first week of sampling. Results will subsequently be compared and rolled into this cumulative average. Daily summaries of all results will be posed on the LMDC’s website.

The EDDs associated with dioxin/furan results will include speciated results for each dioxin/furan congener, the TEEs used, and the TEQ. The EDDs associated with PAH results will include speciated results for each target PAH, the BAP-factors used, and the BAP- equivalent concentration. The EDDs associated with PCB results will include the results for individual Aroclors as well as the result for total PCBs.

14.5 Data Handling and Management

14.5.1 Data Entry and Verification

All data entry performed by TRC or its contractors will be proofed 100% for accuracy. Verification will be carried out either by proofing a printout against the original data or by duplicate entry and comparison of the two data sets to detect discrepancies.

14.5.2 Data Transformation and Reduction

14.5.2.1 Dioxins/Furans Transformation and Reduction

The laboratory will be responsible for calculating the toxicity equivalent quotient (TEQ) for each sample. The TEQ will be calculated using toxicity equivalency factors (TEEs) from Interim Procedures for Estimating Risks Associated With Exposure to Mixtures of Chlorinated Dibenzo- p-Dioxin and Dibenzofurans (CDDs/ CDFs), EPA-625/3-89-016, March 1989. Each dioxin or furan congener is multiplied by the associated TEE. The resulting values from each congener are summed to generate the TEQ. In order to remain conservative, the detection limit for nondetect results will be used and estimated maximum possible concentrations (EMPCs) will be included in the calculations. The TEEs which will be used are as follows:

Dioxin/Furan Congener TEF 2,3,7,8-TCDD_______________ 1.00 2,3,7,8-TCDF________________ 0.1 1,2,3,7,8-PcCDD_____________ 0.50 1,2,3,7,8-PeCDF 0.05 2.3.4.7.8-PeCDF 0.5

L2005-346 Rev. 1

CITY_21MC100_011977842

NYC-WTC_000440652

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000440652Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000441561

Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

Compare copies and versions →