WTC environmental plan, EPA review, 2005

Machine-extracted title · confidence 46%

EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.

NYC-WTC_000437748–000437815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1. Convert the Ca x-ray map to grayscale (Image —> Mode —> Grayscale). 2. Perform an auto contrast and brightness on the map to increase the scale of colors (Image Adjustments Auto Eevels). 3. Threshold the Ca map by going to the Image Menu and choosing Adjustments —> Threshold. Adjust the threshold to 128. The background will be black and the particles white. 4. Invert the image (Image ' Adjustments ^Invert) to make the background white and the particles black. 5. Display a histogram of the image. Place the cursor over the line for the black area and record the percentile for the black area. This is the area percent coverage of particles containing Ca in the entire field.

Determine the maximum area percent coverage of non-gypsum, Ca-rich particles by performing the calculation in Section 13.0.

12.2.5 Particle Analysis for Identification of Gypsum and Concrete.

Place the more dilute sample, deposited directly on the polycarbonate/adhesive tab substrate or prepared by filtration, in the SEM. Particle analysis will be used to identify gypsum and concrete particles.

Perform particle analysis at 500 x magnification. All other operating parameters for the SEM are the same as those used to analyze for slag wool (Section 12.2.1). A binary backscattered electron image should be used in particle analysis mode. Particle analysis parameters should be set to analyze all particles in the field greater than 0.5 pm and to separate touching particles. For particles greater than 5 pm, scan the entire particle; spot analysis is adequate for smaller particles. The x-ray spectrum and counts for all particles, and an image of particles > 20 pm long, will be recorded and saved. Other particle parameters to be reported will include the maximum, minimum, and average diameters, the aspect ratio, and area of each particle.

It will be necessary to review data collected by automated software to ensure data integrity. An Excel spreadsheet, in conjunction with images and x-ray data, may be used for this purpose. Particles should be sorted into one of three categories: Ca-S (gypsum), Ca-rich, and Other. Aid in identification of particles may by facilitated by referencing the U.S. Geological Survey’s WTC Dust Particle Atlas (1). A particle classification protocol will be developed based on the data from the validation study.

The number of particles analyzed will be determined using the results of the validation study. For the study, the area percent of each component should be within 10% relative error or better. Typically, data for 1000 - 1200 particles should be acquired.

46

CITY_21MC100_0 03219535

NYC-WTC_000437793

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437793Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →