NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 68 pages

WTC environmental plan, EPA review, 2005

Machine-extracted title · confidence 46%

EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.

NYC-WTC_000437748–000437815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

fibers per type. Report the slag wool fiber results as the number of slag wool fibers/gram of sample.

12.2.2 EDS Screening for Gypsum/Anhydrite

Place the more concentrated sample deposited directly on the polycarbonate/adhesive tab substrate in the SEM. Choose a random field at lOOx magnification and perform an EDS analysis on the entire field. Look for the presence of sulfur in this field. If sulfur is present, continue to Section 12.2.3 or 12.2.5 for analysis of gypsum and concrete by mapping or particle analysis. If it is not present, repeat the analysis on another random field. If sulfur is still not present, mark the sample as non­ detect (ND) for sulfur.

12.2.3 X-Ray Mapping for Gypsum

Place a more dilute sample, deposited directly on the polycarbonate/adhesive tab substrate or prepared by filtration, in the SEM. Collect binary backscattered electron images (particles white and background black, shadow off) and secondary electron images for 10 non­ overlapping, random fields at 500 x magnification. Collect x-ray maps for Na, Mg, Al, Si, S, Ca, and Fe at each of these fields. Fields containing MMVF will not be used for this analysis. Operating parameters for the SEM are the same as those for analyzing slag wool. Acquisition parameters for x-ray mapping using the NORAN System Six Software are time constant 14 (mapping mode, 11333 cps), 10-20 % deadtime, 256 x 256 image resolution, 20 second frame time, and 100 frames collected (about 40 minutes total acquisition time). Secondary electron images will be used for reference only. Save all of the maps and electron images in TIFF format.

Open the backscattered electron image and the Ca and S x-ray maps in Adobe Photoshop. Make sure that all of the element maps are the same size and resolution by choosing Image Size from the Image Menu and changing the pixel size or the resolution as needed. The presence of gypsum can be determined by overlapping the Ca and S maps.

Perform the following functions in Adobe PhotoShop. (A macro is in development to perform the following functions to decrease user time and human errors in adjusting the threshold.)

1. Convert each of the three images to grayscale (Image Mode —> Grayscale). 2. Perform an auto contrast and brightness on each image and map to increase the scale of colors (Image —> Adjustments —> Auto Levels). 3. Threshold each element map, Ca and S (do not analyze the

44

CITY_21MC100_0 03219533

NYC-WTC_000437791

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437791Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →