Metals/air monitoring table, 100 Church Street, 2002

Machine-extracted title · confidence 30%

Field data for permissible exposures and times during air monitoring at NYC Law Department.

NYC-WTC_000437503
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 6 - Suptemental Report Metals Air Monitoring New York City Law Department 100 Church Street New York

Sample ID: MDAIR 2001 MDAIR 2002 MDAIR 2003 MDAIR 2004 MDAIR 2005 MDAIR 2006 MDAIR 0001 Lab Sample ID: OSHA 1 2 3 4 5 6 7 Sample Date: Permissible 8/9/2002 8/9/2002 8/9/2002 8/9/2002 8/9/2002 8/9/2002 8/9/2002 Stan Time; Exposure Limit 11:00 11;03 11:06 11:10 11:15 11:20 Sample Type; (PEL) niQ/in^ Air Air Air Air Air Air Air Floor ; 20 20 20 20 20 Roof Northwest section, at Southwest next Nofiheast Middle of west Southeastern Shirty Levine's to Jennifer Northeast Location: section section section office Hoo's office Field Blank section

CONSTITUENTS TOTAL METALS (mg/m’) Aluminum <0.00579 U <0.00579 U <0.00579 U <0.00579 U <0.00579 U <0.005 U <0.00579 U Antimony <0.00116 U <0.00116 U <0.00116 U <0.00116 U <0.00116 U <0.001 u <0.00116 U Arsenic <0,000463 U <0 000463 U <0.000463 U <0,000463 U <0.000463 U <0.0004 U <0.000463 U Barium <0.00579 U <0.00579 U <0.00579 U <0.00579 U <0.00579 U <0.005 U <0,00579 U Beryllium <0.000231 U <0.000231 U <0.000231 U <0.000231 U <0.000231 U <0.0002 U <0.000231 U Cadmium <0.000231 U <0.000231 U <0.000231 U <0.000231 U <0.000231 U <0.0002 U <0.000231 U Calcium <0.0579 U <0.0579 U <0.0579 U <0.0579 U <0.0579 U <0.05 U <0.0579 U Chromium 1 0.000840 <0.00579 U 0.000705 0.000984 0.000769 0.000612 0.000788 Cobalt <0.000579 U <0. 73 U <0.000579 U <0.000579 U <0.000579 U <0.0005 U <0.000579 U Copi>er <0.00116 U <0.00116 U <0,00116 U <0.00116 U <0.00116 U <0.001 U <0.00116 U Iron <0.00579 U <0.00579 U <0.00579 U <0.00579 U <0.00579 U <0,005 U <0.00579 U Lead <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.0005 U <0.000579 U Magnesium <0.0579 U <0.0579 U <0.0579 U <0.0579 U <0.0579 U <0.05 U <0.0579 U Manganese <0.000868 U <0.000866 U <0.000868 U <0.000868 U <0.000868 U <0.00075 U <0,000868 U Nickel <0,00116 U <0.00116 U <0.00116 U <0.00116 U <0.00116 U <0.001 U <0.00116 U Potassium <0.0579 U <0,0579 U <0.0579 U <0.0579 U <0.0579 LI <0.05 U <0.0579 U Selenium <0.00116 U <0.00116 U <0.00116 U <0.00116 (J <0.00116 U <0.001 U <0.00116 U Silver <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.0005 U <0.000579 U Sodium <0.0579 U <0.0579 U <0.0579 U <0.0579 U <0.0579 U <0.05 U <0,0579 U Thallium <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.0005 U <0.000579 U Vanadium <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.000579 U <0.0005 U <0 000579 U Zinc <0.00116 U <0.00116 U <0.00116 U <0.00116 U <0.00116 U <0.001 U <0.00116 U

U = Analyzed for but Not Detected

O H

I to

O o o I o

o co co co o TRC Customer-Focused Soluiiorys

NYC-WTC_000437503

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437503Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air monitoring results, metals, Aug 2002

NYC-WTC_000236217

Laboratory report listing air sampling data for metal constituents in various sections of the building on August 9, 2002.

Similar indexed content

Compare copies and versions →