NYC 9/11 Public Portal Document
I ATC Environmental, Inc.
104 East 25th Street
I ATC Associates Inc.
New York, New York 10010
Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date; 09/29/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
I With Fiber Identification by-Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52, No. 210, October 30. 1967
I Sample Identification
Analysis Parameters
Project/Site: 40 Rector Street, NY. NY TEM Sample No.: 5579 - 59740
Foors 6, 7, 3. 4, 11, 2, 1/Lobbv
Date Received: 09/29/01 Grid Openings Analyzed: 6
Project Sample No.: T17 Average Grid Opening: IOS.00 um
Air Volume: 1270 liters ■ Total Area Analyzed: 0.0674 tnni2
1 Filter Type: MCE 25 mm diam., Poi-e Size: 0.45 um
Effective Area: 385 inm2
Analytical Sensitivity: 14.8 s/mm2
0.0D45 s/cc
I FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5uin Struct/mm2 Struct/cc ngm/mS
I Chrysotile Asbestos 0 0 0 0 0 - 0 0.D 0.0000 0
Amphibole Asbestos 0 Q 0 0 0 0 0.0 0.0000 0
I Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Won-Asbestos 0 0 0 0 - 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
I Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED) : None detected
I Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;'
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
I
CITY_21MC100_007087991
NYC-WTC_000437437
OCR can misread numbers and units. Confirm readings against the page image before using them.