NYC Response Asbestos Air Sampling Resuits for Staten island Landfiii Sampling Date and Times; 11/18/01 191S to 11/19/01 074S<“> Data Validation Date; 11/20/2001

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc O.Sp - 5p 5!^ S/mm" S~f/cc‘* Fibers 11/18/01 LF00824 P-1 694 Air <7.0 <0.004 0 0 <8.75 <0.00485 11/18/01 LF00825 P-2 695 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/18/01 LF00826 P-3 693 Air <7.0 <0.004 0 0 <8.75 <0.0049 11/18/01 LF00827 P-4 695 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/18/01 LF00828 P-5 695 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/18/01 LF00829 P-6 693 Air <7.0 <0.004 0 0 <8.75 <0.0049 11/18/01 LF00830 P-7 692 Air <7.0 <0.004 0 0 <8.75 <0.0049 11/18/01 LF00831 P-8 691 Air <7.0 <0.004 0 0 <8.75 <0.0049 11/18/01 S-9A 689 Air NS NS NS NS <8.75 NS 11/18/01 S-9B NS Air NS NS NS NS <8.75 NS 11/18/01 S-10A NS Air NS NS NS NS <8.75 NS 11/18/01 S-10B NS Air NS NS NS NS <8.75 NS 11/18/01 LF00832 W-11 689 Air 20.38 0.011 0 0 <8.75 <0.0049 16 11/18/01 LF00833 W-12A 713 Air 27.39 0.015 NA<” NA<” NA<” NA<” 21.5 11/18/01 LF00834 W-12B 714 Air <7.0 <0.004 0 0 <8.75 <0.0047 11/18/01 LF00835 B-13 694 Air <7.0 <0.004 0 0 <8.75 <0.00485 11/18/01 LF00836 B-14 694 Air <7.0 <0.004 0 0 <8.75 <0.00485 11/18/01 LF00837 T-15 720 Air 7.64 0.004 2*.. 0 17.5 0.0094 6 11/18/01 LF00838 T-16 720 Air 14.01 0.007 NA<” NA<” NA<” NA<” 11 11/18/01 LF00839<“> 0-17 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 11/18/01 LF00840 0-18 720 Air <7.0 <0.004 0 8.75 0.0047 11/18/01 LF00841 Trip Blank 0 Air <7.0 n/a NA("> NA® NA(2> NA® 11/18/01 LF00842 Lot Blank 0 Air <7.0 n/a NA(^> NA® NA(=^> NA®

Key; * Sample volume (liters) is below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile NA <9 - Not analyzed due to overloading of particulates NA - Not analyzed for TEM n/a - Not applicable NIT - Not requested NS - Sample not submitted R - Sample data rejected due to no sample volume NC - Not collected o <“> - The filter for sample LF00839, 0-17, could not be removed during the 11/18/01 evening hours due to the closing off of the area. H The air sample was collected from 11/18/01 0900 to 2100; a total of 720 minutes. The filter was removed on 11/19/01 am.

NiOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, issue 2, 8/15/94 to Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) S o Standard criteria; EPA 40GFR Part 763 (AHERAy O.GI fiber/cc (PCM), 70 S/nim^ volume 1200 L, for 25 mm filter (TEM)

o o Io Ln o to

o o co

NYC-WTC_000437185

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437185Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →