NYC 9/11 Public Portal Document
n
Industrial Hygiene Air Sample Results
Summary for Week of 2/2/02 to 2/8/02
Attached is a summary of die laboratory results completed during die week of February 2, 2002 to
February 8, 2002. The air samples were collected by ATC associates at the World Trade Center site.
The majority of the samples collected by ATC are “personal samples”, meaning that the worker wore
the sampling device. In addition, the most of results have shown exposure levels to be below shift
adjusted occupational exposure limits. The exceptions were;
• Diesel exhaust particulate concentrations at 118% and 77% of the shift adjusted
OEL for a haul tnick operator in depression at the Tower #1 site and for a truck washer
at Pier 25.
• Quartz concentration of 4583%, 2000%, 920% and 833% of the shift adjusted OEL
on three workers breaking concrete with jackhammers in WTC 6 and one worker
breaking concrete at die SE Tower Site.
• Respirable dust concentrations of 171% 104%, and 272% of the shift adjusted OEL
on two workers breaking concrete with jackhammers in WTC 6.
• A carbon monoxide concentration of 359% of the shift adjusted OEL and 153% of
the peak on a torch cutter at the Bl level of WTC 6.
• A noise exposure level of 400% of the shift adjusted OEL on an operator of an auto
jackhammer.
In addition, the following results are at or above 50% of the shift adjusted OEL (but below 100% of
the shift adjusted OEL). The operations associated with these results should receive attention to
ensure diat diese results are an accurate reflection of actual exposures and diat feasible steps are
taken in an attempt to ensure that exposures do not elevate over time;
• Diesel exhaust particulate concentrations of 63% on a torch cutter near the Verizon
Bldg.
• A fiber count (asbestos) concentration of 56%, 60% and 86% of the shift adjusted
OEL on a spotter at Church & Vesey, on a grappler operator at Tower 2 site and a
spotter at the North Tower site.
• Quartz concentration of 67% and 75% of the shift adjusted OEL a boring machine
operator and on a laborer nearby a boring machine.
Some of the columns in the attached summary may require explanation:
Analyte Class - This column includes general category of the agents (substances) which were
sampled.
# of Samples - This indicates how many individual samples were collected for the agent class listed.
# of Analysis - This is the number of individual analyses performed. If only one analysis is
performed on each sample, then the number of analytes will equal the number of samples. Elowever,
most samples are analyzed for more than one agent as follows:
CITY_21MC100_0 03254096
NYC-WTC_000437153
OCR can misread numbers and units. Confirm readings against the page image before using them.