Mr. Bernard P. Orlan June 28, 2002 Environmental Wipe & Bulk Samples Page 2 Stuvvesant Hieh School ('M477) ATC Project No. 15-19125-0246

B. LEAD WIPE SAMPLING -HVAC UNITS

A total of fifteen (15) dust wipe samples were collected from various HVAC units throughout the school. Laboratory analysis detected lead concentrations which ranged between 253.0 qg/ft" to less than the limit of detection of 9.0 qg/ft^. The average concentration was 89.16 qg/ft^.

The sample locations and analytical laboratory results are included in Appendix A of this report.

C. DIOXIN BULK SAMPLING

ATC collected twenty-four (24) samples for PCDDs/PCDFs (plus two blanks) within Unit Ventilators and HVAC units. All samples were submitted for laboratory analysis to Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by modified EPA Method 8290 using combined capillary column gas chromatography/high resolution mass spectrometry.

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value for the analytical results for each sample.

Sample results were compared to the New York State Department of Environmental Conservation (NYSDEC) established guidelines of 0.6 parts per billion (0.6 ppb) for allowable dioxin levels in soil as per NYSDEC Memorandum HWR-94-4046, dated January 24,1994.

The analytical results for the samples collected are as follows: 1. UNIT VENTILATORS

A total of ten (10) bulk samples were collected from settled dust within selected unit ventilators on the north and south sides of the building. Dioxin concentrations ranged from 0.000037 ppb to 0.003100 ppb. The concentration of dioxins in all samples collected from settled dust located within the unit ventilators are below the NYSDEC guideline of 0.6 ppb for allowable concentrations of dioxins in soil.

2. HVAC UNITS

A total of fourteen (14) bulk samples were collected from settled dust within the HVAC system in various locations. Dioxin concentrations ranged from 0.0000046 ppb to 0.000160 ppb.

CITY_21MC100_010214219

NYC-WTC_000437007

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437007Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →