NYC 9/11 Public Portal Document

STRATEGIES FOR ASSESSING THE QUALITY OF AIR IN THE INDOOR ENVIRONMENT

(a) Quantify suspected pollutants, beyond the baseline indicators of indoor air quality evaluated in Phase 1; (b) Determine effectiveness of ventilation system performance through comprehensive system performance evaluations; (c) Identify health evaluations for affected occupants: (d) Formulate hypothesis and identify, or rule out, potential causes of indoor air quality problems; and (e) Develop recommendations for remedial actions.

Elements of the Investigation

• Conduct time weighted average air monitoring for suspected contaminants identified in Phase 1, in areas of concern and control sites. Typical materials that would be evaluated include formaldehyde, dust, volatile organic compounds, bioaerosols (bacteria and fungi) and ozone. Samples of water from cooling towers or air conditioning condensation drip pans may be collected and analyzed for biological agents. Other factors such as noise, lighting and ergonomics are also evaluated for their potential contribution. • Conduct an engineering analysis of the functioning of the building ventilation system and determine if the system is operating as designed. The evaluation includes a review of the design to determine the adequacy of the system to provide for acceptable indoor air quality based on the guidelines of ASHRAE. The impact of building renovations and remodeling are also assessed to evaluate the impact on the effective functioning of the ventilation system. • Distribute questionnaires to large numbers of building occupants to obtain further information regarding the types of complaints and timing and location patterns. A careful analysis of the questionnaires is conducted to further define the patterns of health and comfort complaints. • Evaluations of the medical health of affected employees are conducted to review the health consequences of exposure and attempt to correlate with identified contaminants or conditions. • Results of monitoring and ventilation system evaluations should begin to indicate potential sources or rule out suspected causes. Hypothesis are formulated based on the data obtained and remedial control solutions are developed.

DELIVERABLES

Page 3

CITY_21MC100_002984703

NYC-WTC_000436880

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436880Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →