STRATEGIES FOR ASSESSING THE QUALITY OF AIR IN THE INDOOR ENVIRONMENT

(b) Evaluate the ability of the heating, ventilation, and air-conditioning (HVAC) system to effectively remove airborne contaminants before they enter the breathing zone of the occupants; (c) Determine the potential for adverse health impacts resulting from current indoor air quality conditions; (d) Formulate hypotliesis and identify, or rule out, potential causes of indoor air quality problems; and (e) Develop recommendations for remedial controls.

Elements of the Investigation:

• Review the operation and control of the ventilation system with respect to its ability to provide the quantity and quality of air required to meet the occupants needs. Critical concerns include the provision of adequate quantities of fresh, outside air and local exhaust ventilation for significant point sources of indoor pollutants. Levels of carbon dioxide accumulation will be compared to guidelines for comfort control in buildings developed by the American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE). • Evaluate point sources of indoor air pollution through a careful examination of the use of floor space, and by conducting a walk-through survey of the space with a building representative to identify patterns of air movement with respect to potential generators and receptors of indoor air contaminants. • The location of the HVAC system intakes will be examined to assess the potential for entrainment of pollutants, such as diesel and auto exhaust (from loading docks, parking and loading zones, and emergency generators). The proximity and direction of the intakes will be examined for their potential to entrain microorganisms (such as Legionella) or biocide chemicals from cooling towers. • Conduct interviews with individuals familiar with specific complaints attributed to the building's air quality and with the general operation of the building. • Collect baseline measurements of typical indoor air quality indicators such as carbon dioxide, carbon monoxide, temperature and humidity.

PHASE 2 DETAILED INDOOR AIR QUALITY EVALUATION

Purpose

Page 2

CITY_21MC100_006628469

NYC-WTC_000416759

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000416759Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →