three sequential time periods after simulated restoration work is completed. Pump flow rates will be set to ensure that a minimum volume of at least 1,200 L will be collected during each 3- hour sampling period (e.g., 7-8 L/min). Analysis of these samples will be done using the AHERA method (USEPA 1987). A property will be considered suitable for re-habitation if the final clearance sample complies with the AHERA standard or a more stringent standard, as directed by the NYC Department of Health. If the final clearance sample fails this standard, either more clearance samples may be collected, or alternatively, the pre-activity sample may be analyzed. In this case, the residence will be considered suitable for re-habitation if the final clearance sample does not have a fiber concentration higher than the pre-activity sample.

The following tables provides an example schedule summarizing the that will be collected for this scenario:

Work area Main living area Time Period Example Cloek time Type Min Vol (L) Type Min Vol (L)

Pre-sampling 8:00AM-l 1:00AM Fixed 1200 Fixed 1200

Simulated restoration ll:00AM-12:00PM Personal 14 Fixed 400

Post activity 1 12:00PM-3:00PM Fixed 1200 Fixed 1200 Post activity 2 3:00PM-6:00PM Fixed 1200 Fixed 1200 Post Activity 3 6:00 PM-9:00 PM Fixed 1200 Fixed 1200

Dust Monitors

In addition to sampling for asbestos, two real-time aerosol monitors will be used to quantify the level of dust particles in the air before, during, and after the simulated restoration activities. One aerosol monitor will be located in close proximity to the stationary air monitor, and the other will be located in the enclosed area where the simulated restoration is occurring.

Bulk Dust

In all locations where simulated restoration activities are performed, samples of the bulk dust will be collected and analyzed for asbestos in accordance with NIOSH Method 9002, or using improved methods currently being developed by USEPA for use on this project.

Scenario 4: Sampling During Exterior Cleanup Activities

Sites will be selected for inclusion in this test scenario based on the results of previous solid media and ambient air sampling results. One area will be selected where debris and/or dust does not contain visible fiber and where PLM and/or Infrared analyses do not reveal the presence of asbestos material. Two areas will be selected where fibrous dust or debris is visible and/or where PLM analysis reveals the presence of asbestos fibers. Sampling will be performed when

CITY_21MC100_011206005

NYC-WTC_000436812

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436812Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →