been closely associated with adverse health effects (i.e., cancer). Note that the terms "structures" and "fibers" are used interchangeably in this paper. As per AHERA counting rules, structures may be classified as fibers, bundles, clusters, or matrices. Structures also include asbestiform cleavage fragments meeting the minimum length and aspect ratio described above.

SVF. There is no standard method for airborne or wiped SVF analyses; therefore, we utilized a procedure, developed by EMSL Laboratories, that was based on an asbestos analytical method (12}.

Dioxin. The health-based benchmark for dioxin is based on 2.3,7,8-tetrachlorodibenzo-p- dioxin (2,3,7,8-TCDD) equivalents and the toxicity equivalence method (TEQ) that account for the varying toxicity of the several congener groups (20}. Each dioxin test result, reported as TEQ values in 2,3,7,8-TCDD equivalents, also represents the estimated maximum potential concentration (EMPC) for that sample. The TEQ EMPC value included analysis results that indicated the presence of a congener above zero but may not have met all of the quality assurance and quality control reporting level criteria.

PAHs. The health-based benchmark for PAHs is based on benzo[a]pyrene equivalencies that account for the varying toxicity of the seven compounds ranked as probable human carcinogens (B2) in ERA'S Integrated Risk Information System (8). Analysis results for PAHs are reported as toxicity equivalency factors (TEF) values. These values are the sums of the seven B2 PAHs, modified to reflect benzo[a]pyrene equivalents. The PAHs analysis could potentially identify an additional 16 PAHs (23 total); however, these additional compounds are less toxic and, in general, are not carcinogenic. Therefore, they are not included in the TEF calcula tions.

Quality Control. Quality control (QC) samples including duplicate samples, lot blanks, field blanks, and spiked samples, were collected to assess and to ensure that the sampling and analytical processes were conducted properly. These QC samples were identified as if they were actual samples and were shipped with actual field samples for analysis. Results of the QC blank samples indicated that there was not any contamination above the reporting limit. Results for the field spike wipe samples for lead met the percent recovery QC limit except for two samples that were marginally below the QC limit.

Results

Summary data for asbestos, SVF, lead, dioxin, PAHs, and alpha-quartz are shown in Tables http://pubs.acs.orq/cai- bin/article.cgi/esthag/2004/38/i24/htmi/es035468r.htmi#es035468rt00003 http://pubs.acs

CITY_21MC100_009137575

NYC-WTC_000436537

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436537Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

Compare copies and versions →