NYC-WTC_000243806
Environmental assessment for 100 Church Street prepared by TRC Engineers.
37 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
NYC-WTC_000243668–000243702OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Using TEM, asbestos fibers, bundles, clusters or matrices are counted as structures. A structure is considered part of this group (i.e., a coimtable fiber) based on geometric and dimensional criteria. That is, a structure must satisfy size requirements (greater than 0.5 micrometers long) and have an aspect (length to width) ratio of greater than 5 to 1. All structures fitting these criteria are counted. The method allows the analyst to distinguish between asbestos and non-asbestos structures.
The airborne structure concentration is calculated by proportioning the structures counted per area of filter to the total filter area. The result is an expression of the concentration of airborne asbestos in structures per square millimeter (s/mm^).
4.5.2 Metals Sampling and Results Thirty-five (35) air samples, including blanks, were collected and analyzed for twenty-two (22) metals. Results of metals air samples are presented in Table 11 of Appendix A. A review of the results indicate that most of the air samples were found to be below the analytical detection limit for metals. Only two (2) air samples were found to contain measurable concentrations of metals in the air and for those samples, only lead was detected in one and aluminum was detected in the other. For those two samples in which measurable concentrations of specific metals were identified, all air concentrations were much lower than their respective OSHA permissible exposure limits (PELs).
4.5.3 Volatile Organic Compounds Sampling and Results Eight (8) air samples were collected and analyzed for twenty-three (23) volatile organic compounds (VOCs). Results of VOC air samples are presented in Table 12 of Appendix A. While measurable concentrations of specific VOCs were identified in some of the air samples, all air concentrations were much lower than their respective OSHA PELs.
4.5.4 PAHs Eight (8) air samples were collected and analyzed for semi-volatile organic compounds polynuclear aromatic hydrocarbons (PAHs) (16 individual semi-volatile compounds). Results of PAH air samples are presented in Table 13 of Appendix A. A review of the data indicates that all of the results were below the analytical detection limit for PAH compounds.
22
CITY_21 MC100_014587069
NYC-WTC_000243692
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000243806
Environmental assessment for 100 Church Street prepared by TRC Engineers.
37 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
37 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
37 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
37 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243532
EIA report for 100 Church Street preparation by TRC Engineers.
37 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
20 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
15 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
15 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162612
Correspondence discussing the scope of work and environmental specialist comments for asbestos cleanup at 114 Liberty Street.
16 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435156
Ambient and indoor sampling protocol for WTC-related residential buildings, foreword Feb 2002.
15 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417471
Indoor and dust sampling protocol for residential buildings near WTC, Feb 2002.
15 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139656
Forwarded spreadsheet compiling residential asbestos sampling results collected in November-December 2001, including Building 11 reoccupancy assessment.
15 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000243806
Environmental assessment for 100 Church Street prepared by TRC Engineers.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243532
EIA report for 100 Church Street preparation by TRC Engineers.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096973
Letter from a property director providing an assessment of environmental cleanup activities at 455 North End Avenue.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000243806
Environmental assessment for 100 Church Street prepared by TRC Engineers.
Similar indexed content
NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
Similar indexed content
EIA report for Law Department project at 100 Church Street by TRC.
Similar indexed content
NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
Similar indexed content
EIA report for 100 Church Street preparation by TRC Engineers.
Similar indexed content