NYC 9/11 Public Portal Document

NYC Response Asbestos Air Sampling Results for Staten island Landfill Sampling Date and Timsjs: 01/16/02 b?'1Sto2300 Date VaSidatioii Date; 01/18/2002

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampiing Sampiing Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc O.Sp - 5p 514 S/mm" S~f/cc‘* 01/16/02 LF02213 P-1 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02214 P-2 491 Air <7.0 <0.0055 0 0 <7.87 <0.0062 01/16/02 LF02215 P-3 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF022f6 P-4 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02217 P-5 714 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02218 P-6 NS Air NS NS NS NS NS NS 01/16/02 LF02219 P-7 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02220 P-8 578 Air <7.0 <0.005 0 0 <8.75 <0.0058 01/16/02 LF0222f W-11 720 Air 15.29 0.008 17.50 0.0094 01/16/02 LF02222 W-12A 720 Air 11.46 0.006 0 0 <8.75 <0.0047 01/16/02 LF02223 W-12B 720 Air 13.38 0.007 0 0 <8.75 <0.0047 01/16/02 LF02224 B-13 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02225 B-14 720 Air <7.0 <0.004 2*.. 0 17.50 0.0094 01/16/02 LF02226 T-15 720 Air 26.75 0.014 0 0 <8.75 <0.0047 01/16/02 LF02227 T-16 720 Air 7.64 0.004 0 0 <8.75 <0.0047 01/16/02 LF02228 0-17 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02229 0-18 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02230 0-19 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 01/16/02 LF02231 MPHS-20 698 Air <7.0 <0.004 0 0 <8.75 <0.0048 01/16/02 LF02232 Lot Blank 0 Air <7.0 n/a 0 0 NA® NA® 01/16/02 LF02233 Trip Blank 0 Air <7.0 n/a 0 0 NA’^'i NA’^'l

Key: * Sample volume (liters) is below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile

NA - Not analyzed due to overloading of particulates NA - Not analyzed for TEM n/a - Not applicable NR - Not requested NS - Sample not submitted R - Sample data rejected due to no sample volume NC - Sample not collected NS - Sample not submitted

O NiOSH 740G; Fiber Anaiysis of Air samples via NiOSH 74G0, Rsvision 3, issue 2, 8/15'94 Asbestos Fiber Analysis by Transmission Eiectron Microscopy (TEM) EPA 40GFR Part 763 (AHERA) H Standard criteria: EPA 40CFR Part 763 (AHERA);0.G1 iiber/cc (PCM), 70 S/mmL volume 1200 L, for 25 mm filter (TEM) to S o o o I Ln o

to o to co Ui

NYC-WTC_000436369

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436369Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →