WTC Tremolite fiber monitoring, 2000

Machine-extracted title · confidence 41%

Coordination and monitoring for asbestos-related Tremolite fiber sampling.

NYC-WTC_000435232–000435267
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EPA R8 Multimedia Asbestos Sampling: Libby,MT January 4, 2000

Table 1. DQOs for Primary Objective: Evaluate the Need for Time-Critical Action

DQO Step Description

1. Define the problem The citizens of Libby appear to have an increased incidence of asbestos-related disease, but there are no data to determine if this disease is attributable solely to historic exposures, or whether current exposures are of continuing health concern. 2. Identify the decision Is time-critical action needed to protect public health? If yes, identify appropriate action and intervene as necessary If no, determine whether or not non-time-critical remediation is necessary 3. Identify inputs to decision Level of concern for human health (lifetime excess cancer risk of 1E-03) Estimate of airborne asbestos concentration, and cancer risk per unit concentration.

4. Define study boundaries Spatial bounds-. Community of Libby, including former mining, milling and processing areas and areas potentially impacted as defined by meteorological conditions. If necessary, appropriate background areas are also included (precise locations to be defined). Temporal bounds-, multiple air samples will be collected in areas associated with former mining activities near the town seasonally throughout the year 5. Define decision rule If asbestos levels in indoor air > 1 E-03 risk level, consider the need for time-critical intervention. If asbestos levels in indoor air < 1 E-03 risk level, time-critical intervention may not be necessary. However, additional studies may be needed to determine if non-time-critical remediation is necessary, or if levels might exceed 1 E-03 risk levels under different conditions (e.g., seasonal variation) 6. Specify limits on decision Risk management decisions will be based on the highest airborne asbestos concentration found in any Q errors residential or occupational building. H

7. Optimize the design Incorporate new information as data become available on actual airborne exposure and risk levels. S o I—i o o Io o LO

14 LO

(JI

NYC-WTC_000435248

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000435248Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →