Air sampling results, Stuyvesant High (Tent testing), Aug 2002

Machine-extracted title · confidence 32%

Air sampling results from controlled carpet cleaning at Stuyvesant High School, with TEM analysis data.

NYC-WTC_000434663
Page image
Scanned page image, NYC-WTC_000434663
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

August 28, 2002

Mr. Alex Eempert Director, Industrial and Environmental Hygiene Division New York City School Construction Authority 30-30 Thomson Avenue Long Island City, NY 11101

RE: Stuyvesant High School, 345 Chambers Street, New York, NY NYC SCA Project #: M477-15217, LEW#: 29881

Dear Mr. Lempert, On August 20, 2002, Kiss Construction, Inc. (“KCI”) under the supervision of Taylor Environmental Group, Inc. (“TEG”) performed controlled carpet cleaning procedures at the aforementioned facility. The cleaning procedures and associated au-monitoring was performed in strict compliance with the protocol as defined in the attached UET Memorandum dated August 14, 2002. As defined in the UET Protocol, five (5) air-samples were collected inside each tent. All air-samples collected were analyzed via TEM (AHERA Protocol). A 20" Box Pan was installed inside each tent and operated for the duration of the air-sampling. Air-Monitoring Results Summary

Auditorium - Tent #1 (Carpet Cleaning) Sample # Results (as/mm^)* AE-6 <16.0__________ AF-7 40.0___________ AF-8 <16.0 AF-9 <16.0 AF-10 96.0 * - as/nm2 = Asbestos Structures per millimeter squared

At the request of the NYC SCA sample #AF-10 was reanalyzed by viewing different grid openings than the original analysis and indicated an asbestos structure concentration of 48 as/mm^.

Please note that the average asbestos structure concentration of the five samples collected within the enclosure is less than the AHERA clearance level of 70 as/mm^

If you have any questions, or require further information, please do not hesitate to call. I hope we have satisfactorily assisted you in your environmental health concerns. Sincerely,

George Taylor

1

CITY_21MC100_013073909

NYC-WTC_000434663

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000434663Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000433384

SCA memo summarizing Stuyvesant High School project scope and participants.

Similar indexed content

NYC-WTC_000431535

Memo documenting environmental consulting and asbestos/lead paint services for Stuyvesant High School project.

Similar indexed content

Compare copies and versions →