The following provides the results of our review of the above-described data submitted to you by the residents of 114 Liberty Street:

Asbestos Data

Based on the results that were received, it appears that eleven wipe samples and sixteen micro vacuum samples were collected by Ambient Group Inc. and analyzed by EMSL Analytical Inc. for asbestos. An additional wipe sample and two microvacuum samples were submitted as blanks. A summary of the results is presented below.

Location Matrix Sample Average Maximum Size Concentration Concentration (s/cnr) (s/cm^) All locations Wipe if 4.327.650 Below floor Wipe 1 11,681 Wall Tracking Wipe 9 726,108 4,327,650 Below Light Wipe 1 8,652 Switch Blank Wipe 1 2,164 All Locations Microvacuum li 284.488 1.11.5.570 Below Floor Microvacuum 10 369,830 1,115,570 Wall Tracking Microvacuum 1 15,058 I-beam Microvacuum 7,636 8,038 (ND) Column Microvacuum 1 8,038 (ND) Pipe Shaft Microvacuum 1 71,592 Front Office Microvacuum 1 743,552 Blank Microvacuum 9 803

ND= asbestos not detected

The interpretation of these results is constrained by the scientific uncertainty regarding the potential for the measured concentrations in settled dust to become airborne. There are no standards currently available for assessing potential health consequences from asbestos through the evaluation of wipe or microvacuum samples. A scientific peer review panel (World Trade Center October 21- 22, 2002 Peer Review Meeting Notes. Available at www.tera.org.) recently evaluated the technical soundness of estimating airborne asbestos concentration as a function of asbestos concentration in settled dust for the purpose of setting health-based benchmarks. The panel recommended against such an approach based on the significant uncertainty associated with the numerous factors (such as activity patterns, sample location, surface characteristics, air exchange rates and room volume) that influence this relationship. EPA’s use of surface wipe and microvacuum sampling at its WTC Residential Confirmation Cleaning Study site (110 Liberty St) was intended to provide a measure of cleaning effectiveness, and not a risk-based health assessment.

CITY_21MC100_009481720

NYC-WTC_000433836

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000433836Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →