NYC 9/11 Public Portal Document
cleaning operation were all non-detected for asbestos. These samples were also
analyzed for fibrous glass, which was found at levels from non-detected to 0.22
f/cc, well below established exposure limits.
The one remaining positive bulk sample for asbestos, which contained 0.06%
asbestos, was taken from a windowsill during a scope A job. Asbestos air
samples were taken during the cleaning operations, all of which were non
detected for asbestos. A bulk paint chip sample was also taken from a
windowsill in the same apartment above the window trough. Sample results
indicated the paint chip contained 6% lead. Wipe sample results for this location
revealed lead levels were 45ug/1 OOcm^. Air sampling for metals during this job
verified work practice efficacy, as the results were non-detected for lead and
other metals. Please refer to the discussion of the above lead wipe sample result
in the Wipe Sampling section of this report.
Two bulk samples for metals that were taken during other inspections indicated
levels of lead ranging from 0.02% to 0.33%. Air sampling for metals was also
conducted during the cleaning operations where these bulk samples were taken.
Metals, including lead, were not detected.
Air Sampling
Asbestos
Asbestos sampling was conducted during virtually every inspection this reporting
period. All samples were non-detected for asbestos using Phase Contrast
Microscopy (PCM).
Fibrous Glass
Sampling for fibrous glass was also conducted during the majority of inspections.
Fibrous glass was detected in four air samples. All of these sample results
indicated exposure to significantly less than 1 fiber per cubic centimeter of air.
Glass fiber exposures in these cases ranged from 0.0032 to 0.22 fibers/cm^, well
below published exposure limits for this substance. It should be noted that
OSHA’s PEL for fibrous glass is currently 15mg/m^ for total dust and 5mg/m^ for
respirable dust. The ACGIH TLV for synthetic vitreous fibers (including glass
fibers) is 5mg/m^ or If/cm®. For this project OSHA is using the more protective
exposure limit of If/cm® for comparative purposes only. Total particulate and
gravimetric analysis of total dust samples indicated exposures to all particulate
matter including fibrous glass, if present, was significantly less than these
exposure limits. See discussion regarding total/respirable dust sampling below.
4
CITY_21MC100_011406021
NYC-WTC_000433170
OCR can misread numbers and units. Confirm readings against the page image before using them.