NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 08-09-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
2nd Floor
PROJECT NUMBER: M477-15217/29881
SAMPLED BY: Client
SAMPLE DATE 08-08-02
DATE RECEIVED: 08-09-02
DATE ANALYZED: 08-09-02
SAMPLE MEDIA: Air Samples
ANALYSIS REQUIRED: Method NIOSH 7082
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(gg/m’) (gg/m’)
AL-01 21025 Rm 250 by Entrance <2.0 2.0
AL-02 21025 Rm 251 by Entrance <2.0 2.0
AL-03 21025 Rm 273 by Entrance <2.0 2.0
BL3 21025 Field Blank <1.5 gg 1.5 gg
BL4 21025 Field Blank <1-5 gg 1.5 pg
AL-04 21025 In Rm 103 Center <1.1 1.1
AL-05 21025 In Rm 105 by Door <1.1 1.1
AL-06 21025 In Rm 103 Center <1.3 1.3
AL-07 21025 In Rm 105 by Door <1.3 1.3
BLl 21025 Field Blank <1-5 gg 1.5 gg
BL2 21025 Field Blank <1.5 gg 1.5 gg
NOTEl:
THE REPORTING LIMIT (RL) IS 3.0 gg
NOTE 2:
At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However, OSHA has
established an action level of 30 gg/m’ and a permissible exposure level (PEL) of 50 gg/m’ for personal samples.
NOTE 3:
Blank units are in gg
CITY_21MC100_010234604
NYC-WTC_000432837