ATC ASSOCIATES, INC 104 E 25th Street, 10th Floor New York, NY 10010 Tel. 212-353-8280 Fax 212-353-8306

REPORT DATE: 07-30-02

CLIENT: Taylor Environmental Group, Inc.

PROJECT NAME: SCA/Stuyvesant HS 2nd Floor

PROJECT NUMBER: M477-15217/29881

SAMPLED BY: Client

SAMPLE DATE 07-29-02 DATE RECEIVED: 07-29-02 DATE ANALYZED: 07-29-02

SAMPLE MEDIA: Air Samples ANALYSIS REQUIRED: Method NIOSH 7082

ANALYSIS RESULTS

SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION ID NO. CONCENTRATION LIMIT (Pg/m’) (Pg/m’)

1 20745 Inside Rm 207 at Entrance to Corridor <3.1 3.1

2 20745 Inside Rm 209 at Entrance to Corridor <3.1 3.1

3 20745 Inside Rm 229 at Entrance to Corridor <3.1 3.1

4 20745 Inside Rm 235 at Entrance to Corridor <3.1 3.1

5 20745 Inside Rm 237 at Entrance to Corridor 3.2 3.1

6 20745 Inside Rm 250 at Entrance to Corridor <3.8 3.8

7 20745 Inside Rm 251 at Entrance to Corridor <4.9 4.9

8 20745 Field Blank <1.5 gg L5 gg

9 20745 Field Blank <1.5 gg 1.5 gg

NOTE 1: THE REPORTING LIMIT (RL) IS 3.0 gg “ NOTE 2: At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However, OSHA has established an action level of 30 gg/m’ and a permissible exposure level (PEL) of 50 gg/m’ for personal samples. NOTES: Blank units are in gg

CITY_21MC100_010234556

NYC-WTC_000432797

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000432797Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →