NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 07-29-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
3rd Floor
PROJECT NUMBER: M477-15217/29881
SAMPLED BY: Client
SAMPLE DATE 07-28-02
DATE RECEIVED: 07-28-02
DATE ANALYZED: 07-28-02
SAMPLE MEDIA: Air Samples
ANALYSIS REQUIRED: Method NIOSH 7082
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(ng/m’) (ng/m’)
01 20722 Inside Rm 301A by Entrance 4.4 3.4
02 20722 Inside Rm 303 by Entrance 5,9 3.4
03 20722 Inside Rm 305 by Entrance 4.0 3.4
04 20722 Inside Rm 325 by Entrance 5.4 3.4
05 20722 Inside Rm 301A by Entrance' 4.4 3.6
06 20722 Inside Rm 303 by Entrance <3.6 3.6
07 20722 Inside Rm 305 by Entrance <3.6 3.6
08 20722 Inside Rm 325 by Entrance <3.6 3.6
09 20722 Field Blank <1-5 ng L5 ng
10 20722 Field Blank <1-5 ng 1-5 ng
NOTEl:
THE REPORTING LIMIT (RL) IS 3.0 pg
NOTE 2:
At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However, OSHA has
established an action level of 30 ng/m’ and a permissible exposure level (PEL) of 50 ng/m’ for personal samples.
NOTES:
Blank units are in pg
CITY_21MC100_010234551
NYC-WTC_000432793