NYC 9/11 Public Portal Document
i
OSHA SAMPLING RESULTS SUMMARY AS OF 12/18
Asbestos: A total of 872 air monitoring sanqsles for asbestos have been taken. From 9/13 -9/21, 177
samples were taken in die financial district They were taken on OSHA personnel as they
walked within certain predetermined zones. Results revealed asbestos concentrations ranging
from ND (none detected) to .037 free., weU below OSHA’s permissible exposure limit (PEL)
of .1 free. After 9/21, sanqjling focused on the rubble pile and those workers working on or
immediately next to it 82 of the sanpies analyzed exceeded OSHA’s limit via PCM analysis.
However, upon further analysis using discr ting counting methods! and/or TEM analysis,
the number of asbestos fibers found dropped dramatically to below detectable levels or well
below .1 free.
Carbon Monoxide: A total of 77 personal samples of workers on the rubble pile showed results ranging from 1
ppm to 34 ppm which are weU below the OSHA 50 ppm permissible exposure limit
Noise: OSHA has been conducting noise monitoring in the rubble pile. 41 personal samples have been
conducted on employees performing (or working near) various operations such as jack
hammering, drilling and equipment operations. Enqrloyee’s exposure to the noise range from
73.7 dBA to 94.5 dBA. OSHA’s permissible noise exposure for constraction is 90 dBA. One
personal sample and one area sample during core drilling operations exceeded the OSHA noise
PEL of 90 dBA. OSHA continues to recommend the use of appropriate hearing protection
for workers performing tasks where high noise levels are likely to be encountered.
Respirable
Silica: The overwhelming majority of the 391 silica samples show no detectable levels of airborne
silica. However, thirteen exposures exceeded the PEL. The higliest sample result was
approximately nine times the OSHA limit (pre-drillers working on the slurry or ‘bathtub”
wall). The other twelve elevated exposures were approximately one to six times the OSHA
limit These exposures occurred during: 1) rubble removal and loading operations near the
Winter Garden; 2) during the breaking up of concrete in the pit; 3) while core drilling the
concrete slurry wall, and 4) while chipping concrete with power tools during demolition
activities at 7 WTC’s parking garage. Most of the work areas ivhere apparent overexposures
to silica occurred were in the rubble pile; an area where OSHA continnes to encourage the use
ofrespiratory protection.
Volatile Organic
Compounds: OSHA has taken 590 sanpies for (VOCs) such as acetaldehyde, acrolein, acrylonitrile,
benzene, 2-butanone, carbofurans, chlorodiphenyl (PCB), ethylbenzene, formaldehyde. Freon
R-22 (chlorodiflouromefhane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene,
phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl chloride, glutaraldehyde,
and xylene. Screening samples initially showed elevated levels of some organic chemicals
resulting from the fires burning in the rubble pile. Subsequent personal and area samples show
worker exposure levels to be below OSHA limits. However, one personal sample result for
benzene was found to be at die 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was
found on a backhoe operator moving debris. See information below for polynuclear aromatics,
Freon R-22, phosgene and dioxin.
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees manning truck wash
stations revealed trace levels of nitric oxide and nitrogen dioxide. SO, personal and area
results were found to be below OSHA limits.
Page 1 of 2
CITY_21MC100_013098645
NYC-WTC_000432046