NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗EPA NYC Region 2 WTC response document, City data file.
NYC-WTC_000431857–000432027OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Baseboard heating components, including the hydronic finned radiation systems, were cleaned. The protective covers were removed to expose the heating elements. The fins were then vacuumed and brushed simultaneously to remove dust. The space located under the heating element was vacuumed. The protective covers were reattached.
Cleaning of Refrigerators, Dishwashers and Stoves (including exhaust fans). Prior to cleaning refrigerators, the appliance was unplugged and checked for food contents. If present, food was removed, bagged and disposed. The coils, underbody, compressor compartment, and back of each refrigerator was cleaned. Dust from the cooling coils was cleaned by elevating the appliance and simultaneously using vacuums and specialized brushes. Upon completing these activities the floor area where the refrigerator had been located was cleaned. Prior to cleaning, each stove unit was disconnected from its electric receptacle and gas line. Old exhaust fan lights and filters were removed and replaced. The first foot of the exhaust duct was vacuumed. The stove hood was vacuumed. Prior to cleaning dishwashers, the toe plate was removed and dust was vacuumed from under the appliance. After cleaning, all appliances were staged on plastic for subsequent removal by the owner, who had decided to replace them.
Pre-Cleaning and Post-Cleaning Sampling. Pre-cleaning and post-cleaning sampling was performed to measure levels of COPC. Sampling data was reviewed and a decision regarding the need for additional cleaning was made. Wipe samples were collected from solid surfaces, both vertical and horizontal. A micro vacuum technique was used on sofas, mattresses, and porous materials. All sampling was conducted in accordance with the Quality Assurance Project Plan (QAPP) contained within Attachment G, Sampling and Analysis Plan.
2.7 Cleaning of Commercial Units, Common Areas and Basement
The cleaning of each commercial unit was accomplished using the vacuum equipment type prescribed by the designated test, as presented in Attachment H, Synopsis of Cleaning by Building Area and Fact Sheets. Management of waste was accomplished as the cleaning activities occurred. The sequence of procedures for vacuuming, wet wiping, waste management, and pre-cleaning and post-cleaning sampling mirrored the procedures used in the residential units. Cleaning of the HVAC systems and carpets presented the only significant differences from the procedures used to clean the residential units. A discussion of the procedures used to clean the HVAC systems and carpets in the commercial units and the procedures used to clean the common areas and the basement follows.
HVAC Systems The Chiropractor’s Office is located in the north end of the building at the Liberty Street address. It contains four patient rooms and an administrative section with a waiting room and a half bath facility. The air conditioning system in the unit is suspended from the third floor deck above a suspended acoustical tiled ceiling, located in the south end of the office space. It utilizes a common closed return to convey air to the blower cabinet. The supply trunk runs northward, supplying air to the balance of the rental space through supply diffuser grills. The system's condenser/compressor unit is located on the building's atrium roof area at the second floor elevation.
The Mattress Store is located in the north end of the building at the Liberty Street address. Space 19
CITY_21MC100_011132898
NYC-WTC_000431879
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
45 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
45 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
32 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
28 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
17 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155286
Formal letter criticizing the EPA and DEP for alleged failures in cleaning asbestos and silica from 114 Liberty Street.
13 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similar indexed content
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similar indexed content
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similar indexed content
NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similar indexed content
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similar indexed content