ATC ASSOCIATES, INC 104 E 25th Street, 10th Floor New York, Nit" 10010 TeL 212-353-8280 Fax 212-353-8306

I REPORT DATE: 07-29-02

CLIENT: Taylor EnviionmentaJ Group, Inc.

PROJECT NAAIE: SCA/Stuyvesam HS 3rd Floor

PROJECT NUMBER; M477-15217/298S1

SAMPLED BY: Client

I SAMPLE DATE DATE RECEIVED: DATE ANALYZED: 07-28-02 07-28-02 07-28-02

SAMPLE MEDIA: -Air Samples ANALYSIS REQUIRED: Method NIOSH 7082

I ANALYSIS RESULTS

I SAMPLE ID BATCH NO. SAMPLE DESCRIPTION LEAD concentration (gg/m’) DETECTION LIMIT

01 20722 Inside Rm 301A by Entrance 4.4 3.4

02 20722 Inside Rm 303 by Entrance 5.9 3.4

03 20722 Inside Rm 305 by Entrance 4.0 3.4

04 20722 Inside Rm 325 by Entrance 5.4 3.4

I 05 20722 Inside Rm 301A by' Entrance 4.4 3.e 06 20722 Inside Rm 303 by' Entrance <3.6 3.6

I 07 20722 Inside Rm 305 by Entrance <3.6 3.6

08 20722 Inside Rm 325 by Entrance <3.6 3.6

09 20722 Field Blank <1.5 Mg 1.5 Mg

10 20722 Field Blank <1-5 Mg 1.5 Mg

I I NOTE 1; THE REPORTING LINDT fRL) IS 3.0 pg NOTE 2: At the present time there are nc regulatory levels or requirements for indoor airborne 'cad in area samples. However, OSH A has

I c.^ubiished an action level of 30 Mg/m’ and a pcrmijssible exposure level (PEL) of 50 pg/n-? for persona] EompJe.s. NOTE 3: Blank units are in pg

I CONFIDENTIAL, CITY_21MC1OO_O1O733942 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000431851

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431851Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →