Lead in Air by Flame AAS, Stuy H.S., Aug 2002

Machine-extracted title · confidence 53%

ATC Associates lab report for lead in air at Stuyvesant High School, Aug 2002.

NYC-WTC_000431708
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES, INC 104 E 25th Street, 10th Floor New York, NY 10010 Tei. 212-353-8280 Fax 212-353-8306

REPORT DATE: 08-07-02

CLIENT: Taylor Environmental Group, Inc.

PROJECT NAME: SCA/Stuyvesant HS 2nd Floor

PROJECT NUMBER: M477-15217/298S1

SAMPLED BY: Client

SAMPLE DATE 08-06-02 DATE RECEIVED: 08-07-02 DATE ANALYZED; 08-07-02

SAMPLE MEDIA: Air Samples ANALYSIS REQUIRED: Method NIOSH 7082

ANALYSIS RESULTS

SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION ID NO. CONCENTRATION LIMIT (pa/mJ) (Hg/'mO

01 209S2 Inside Room 260 near Entrance to Hallway <1.8 l.S

02 20982 Inside Room 201 near Entrance to Hallway <1.8 1.8

03 209S2 Inside Room 260 near Entrance to Hallway <1.7 1.7

04 20982 Inside Room 207 near Entrance to Hallway <1.9 1.9

05 20982 Field Blank <1.5 pg 1 -5 pg

06 20982 Field Blank <1-5 pg 1.5 pg

NOTE 1: THE REPORTING LIMIT (RL) IS 3,0 pg NOTE 2; At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However. OSHA has established an action level of 30 pg/m' and a permissible exposure level (PEL) of 50 pg/m' for personal samples. NOTE 3: Blank units are in pg

CERTIFICATION AND SIGNATURES

ANALYSIS PERFORMED BY:

REPORT PREPARED BY:

ATC cenifies that this report is art accurate and authentic repoi^pf results obtained from the laboratory' analysis.

QUALITY ASSURANCE COORDINATOR:

LABORATORY DIRECTOR: ATC is accredited by the New York State Department of Health Environmental Laboratory Approval Program (ELAP) and by the American Industrial Hygiene Association (AIHA) to perform analysis of lead in paint, dust wipes, air and soil samples. (ELAP #108791, (AIHA #100229).

CITY_21MC100_0 10245519

NYC-WTC_000431708

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431708Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →