NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 07-17-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
345 Chambers St., 9th Floor
SAMPLED BY: Client
SAMPLE DATE 07-16-02
DATE RECEIVED: 07-16-02
DATE ANALYZED: 07-16-02
SAMPLE MEDIA: Air Samples
ANALYSIS REQUIRED: Method NIOSH 7082
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(Pg/m^) (Pg/m’)
01 20398 Rm 901 Inside Classroom Near Entrance to Corridor <3.1 3.1
02 20398 Rm 903 Inside Classroom Near Entrance to Corridor <3.1 3.1
03 20398 Rm 907 Inside Classroom Near Entrance to Corridor <3.1 3.1
04 20398 Rm 911 Inside Classroom Near Entrance to Corridor <3.1 3.1
05 20398 Rm 913 Inside Classroom Near Entrance to Corridor <3.1 3.1
06 20398 Rm 925 Inside Classroom Near Entrance to Corridor <2.5 2.5
07 20398 Rm 901 Inside Classroom Near Entrance to Corridor <3.3 3.3
08 20398 Rm 903 Inside Classroom Near Entrance to Corridor <3.3 3.3
09 20398 Rm 907 Inside Classroom Near Entrance to Corridor <3.3 3.3
10 20398 Rm 911 Inside Classroom Near Entrance to Corridor <3.4 3.4
11 20398 Rm 913 Inside Classroom Near Entrance to Corridor <3.4 3.4
12 20398 Field Blank <1-5 pg 1.5 pg
13 20398 Field Blank <1-5 pg L5 pg
NOTE 1:
THE REPORTING LIMIT (RL) IS 3.0 pg
NOTE 2:
At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However, OSHA has
established an action level of 30 pg/m^ and a permissible exposure level (PEL) of 50 pg/m^ for personal samples.
NOTE 3:
Blank units are in pg
CITY_21MC100_010245388
NYC-WTC_000431605
OCR can misread numbers and units. Confirm readings against the page image before using them.