Asbestos Monitoring at the WTC Site
I (September 13 - 27, 2001)
I
Financial District
I OSHA has taken approximately 40 air and bulk samples in the Financial District
(the location east of Broadway and south of John Street). Results ranged from
"non-detected" to 0.041 fibers per cubic centimeter (f/cc). Further analysis
I showed all fibers to be non-asbestos. Results showed levels consistent with safe
and acceptable standards. OSHA ceased sampling in the Financial District on
Sept. 21.
I Warm Zone
A 90-square block surrounding the World Trade Center complex and plaza has
been designated a secure area with controlled access. It extends south of
Chambers Street, west to Broadway, south to Rector Street and east to near the
Hudson River. OSHA continues to collect samples; more than 150 bulk and air
samples were taken in the "Warm Zone" through Sept. 24. Asbestos levels
I remain safe and consistent, ranging from non-detected to 0.086 f/cc.
Hot Zone/Rubble Pile
I What has come to be known as "ground zero", the hot zone is the World Trade
Center complex area itself. It includes the remains of both WTC towers, 7 WTC,
and other partially collapsed buildings.
I During this time period, OSHA took 65 air samples and seven bulk samples in the
hot zone. Results showed levels ranging from 0.004 to 0,140 f/cc. The level of
0.140 revealed 90 -95% mineral wool fibers and is below safe levels.
I All sampling has resulted in what OSHA considers safe levels of exposure; still,
the agency is recommending workers in the immediate area of the rubble pile
I wear respirators. OSHA continues to conduct monitoring for asbestos throughout
the warm and hot zones. Results will be posted periodically on this page.
To see a grid map showing asbestos monitoring at specific sample locations in
New York click here.
I Permissible Exposure Limit (PEL) for asbestos is 0.1 f/cc as an 8-hour time-
weighted average.
I Excursion Limit(or short-term exposure limit) is 1 f/cc over a 30-minute
period.