Sheetl

Samples Highest Result Highest Analyte Job with Highest # of NQs %NQ CO Peak Week of: Agent Class Collected ’Target % of Target # Analyses % of OEL Exposure # Above 200 ppm

11/25/01 Total DLBt/Metals 9 189% 340 56% of PEL Cadmium Torch Cutter 198 58% 11/25/01 Resp. Dust/Silica 13 7.25 179% 39 36% ot TLV Quartz Spotter 27 69% 11/25/01 Aromatics 14 50% 28 0.0076% ot TLV Toluene Torch Cutter 26 93% 11/25/01 Aldehydes 3 7.5 40% 21 1.3% ot PEL Formaldehyde Backhoe Operator 15 71% 11/25/01 PAHs 6 8 75% 96 2.8% of PEL Napthalene Qrappler Operator 75 78% 11/25/01 Asbestos 24 15.5 155% 24 33% of PEL Fibers Spotter 17% 11/25/01 Adds 6 13.5 44% 36 0.33% of TLV Hydrofluoric Acid Qrappler Operator 59 164% 11/25/01 Ozone 2 5.5 36% /Ml "Too Low to Quantify" 11/25/01 Carbon Monoxide (TWA) 26 22 118% 26 132%ot TLV (abbrexiated Carbon Monoxide Flagman 15 58% 1 @ 230 ppm (Qrappler Operator) sample - 2 hrs, 9 min) 104 102.25 102% 612

12/1/01 Total DLEt/Metals 10 9 111% 202 10% ot PEL Arsenic Torch Cutler 122 60% 12/1/01 Resp. Dust/Silica 8 7.25 110% 24 11% ot TLV Respirable Dust Equipment Operator 19 79% 12/1/01 Aromatics 12 14 86% 48 0.64% ot TLV Benzene Equipment Operator 31 65% 12/1/01 Aldehydes 6 7.5 80% 42 2.3% ot PEL Formaldehyde Equipment Operator 29 69% 12/1/01 PAHs 6 8 75% 96 8.5% ot PEL Total PAHs Torch Cutter 52 54% 12/1/01 Asbestos 26 15.5 168% 26 48% ot PEL Fibers Spotter 5 19% 12/1/01 Adds 6 13.5 44% 36 5.9% ot PEL SdluricAcid Qrappler Operator 31 86% Ozone 8 145% 8 /Ml "Too Low to Quantify" N/A 8 100% Carbon Monoxide (TWA) 18 ’i’ 82% 18 20% of TLV Carbon Monoxide Torch Cutter 14 78% 12/1/01 Hydrogen Sdfide 8 8 100% 8 160% of TLV (Area Sample) Hydrogen SUtide SW Corner, near south bridge 5 63% 12/1/01 Diesel Fume 275% 2.2% of PEL Inorganic Carbon Torch Cutter Totals: 108 114.25 95% 508

Notes:

The PEL tor quartz is determined by the tcrmula PEL = 10 mg/m3 / (% quartz +2). For dusts with high quartz content this works out to be a quartz concentration ot approximately 0.1 mg/m3.

"OEL" = "occupational exposure limit". A generic term encompassing PE_s, TLVs and other workplace exposure limits.

"NQ" = "not quantitiable". Stbstance was was not present in sufticient quantity in the sample to report a tirm value tor the concentration. All quantitication levels tor the sampling methods used are well below occupational exposure limits.

The area samples tor hydrogen sulfide were taken near suspected sources and were not representative ot worker exposure.

o

l"^

S Q O O I Page 1 o o cn

co VO CO

NYC-WTC_000429751

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000429751Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →