o Ambient Air Monitoring Program Section No. 8 o
co
g Quality Assurance Project Plan Revision No.: 0
o 130 Liberty Street - NY, NY Date: August 2005
I Lower Manhattan Development Corporation Page 45 of 116 “0
o c
o CT
o
o'
ro "0
oo o
Ca5
o> 03
CD
Table 8-7. Measurement Performance Criteria Table - Silica by XRD O
QC Sample or Activity DQI o
Frequency Measurement Performance Criteria Corrective Action o
c
Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, qualify Precision-Overall 3
samples are > 5x QL data, and/or resample data. o
3
*No situation where one result is detected
at > 5x QL and other result is not detected
Laboratory Duplicates 1/batch RPD < 20 if results are > 5x detection limit Reanalyze and qualify data. Precision
Method Blanks 1/ batch Silica < detection limit Reclean, retest, reanalyze and/or Accuracy/Bias-
qualify data. Contamination
Field/Trip Blanks 1/day^^’ Silica < detection limit Reclean, retest, reanalyze and/or Accuracy/Bias-
qualify data. Contaminatioii
Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness
Laboratory Control Standards 1/day Percent recoveries 80-120% Recalibrate, reanalyze, and/or Accuracy/Bias
qualify data.
Sample Reanalysis 10% of samples RPD < 100 Recalibrate, reanalyze, and/or Precision
qualify data.
•'’Only analyzed if silica is detected in the associated samples.