8.0 QUALITY OBJECTIVES AND CRITERIA FOR MEASUREMENT DATA
This section provides an overview of the environmental decisions that need to be made and the
level of data quality needed to ensure that these decisions are based on sound scientific data.
8.1 Project Quality Objectives
As discussed in Section 6.2, the principal objective of the air monitoring program is to monitor
air quality in the vicinity of 130 Liberty Street during the deconstruction of the building on that
property. This objective will be satisfied by the sampling and analysis program outlined in
Tables 7-la, 7-lb, 7-lc, 7-2, and 7-3. These tables outline the data needs by type, quantity, and
quality.
The type of data needed to meet the project quality objectives (PQOs) includes the required
contaminants of concern, concentration levels, media to be sampled, analysis type, and
appropriate sampling techniques. These are detailed on Tables 7-la through 7-lc, 7-2, 7-3, and
8-1 and in Section 10.0. The quantity of data needed to meet the PQOs includes the number of
samples for each analytical parameter of each media and a definition of the project boundaries.
The first of these items is detailed on Tables 7-la through 7-lc. The second of these items is
dictated by the Ambient Air Monitoring Program for the 130 Liberty Street Deconstruction
Project, August 2005. The quality of data needed to achieve the PQOs includes the necessary
data quality indicators (precision, accuracy, representativeness, comparability, completeness,
selectivity, and sensitivity) required of each analytical parameter used for each media sampled.
The limits set on each of these items are referred to as measurement performance criteria and
define the quality of data generated. All measurement performance criteria have been
established for each parameter in order to ensure the data are sound, highly defensible, and with
quantitation limits significantly below project action levels.
The type, quantity, and quality of data needed to achieve the objectives listed above were
predetermined. The COCs are outlined in Table 8-1 and include the quantitation limits and
associated project action levels for each contaminant of concern. This table has been completed
for each parameter.
Laboratories will report quantitation limits as low as technically possible and will estimate
values detected below the quantitation limit.
In general, the proposed analytical methodologies will be able to achieve the PQOs. That is, the
analytical methodologies are generally capable of detecting the target analytes well below the
applicable action limit. These methods provide data of known quality and can be used for the
objectives of this program. However, in order to ensure that the analytical methodologies are
capable of achieving the data quality objectives, measurement performance criteria have been set
for the analytical measurements in terms of accuracy, precision, representativeness,
completeness, sensitivity, selectivity, and comparability.