Ambient Air Monitoring Program Section No. 14
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 100 of 116
14.4 Data Deliverables
14.4.1 Field Analysis Data
14.4.1.1 Hardcopy Deliverables
For the field analyses associated with this program, which consist of the gaseous mercury
analysis and PMio and PM2.5 real-time measurements, laboratory data packages are not required.
All field and QC sample results, calibrations, and calibration verifications will be recorded in the
field logbook, on field screening forms, and on equipment calibration forms to ensure proper
verification of the sample results.
14.4.1.2 Electronic Deliverables
Real-time data (i.e., PMio and PM2.5) will be downloaded daily from data loggers using cellular
telephone modems on each monitor. Ten-minute averages from each station will be transmitted
to a central station. Daily plots of real-time data will be generated. Twenty-four hour averages
of PMio and PM2 5 will be calculated using these data and included on the daily summaries
posted on the LMDC website. Graphical presentation of PMio and PM2.5 data will be provided
on a weekly basis. The gaseous mercury results will be noted on a form during the collection of
data. These results will be hand-entered into the central station and included on the daily
summaries posed on the LMDC website. The data from the meteorological station units will be
recorded by a CSICR510 digital data logger, and telemetered back via CDMA cellular modems.
14.4.2 Fixed Laboratory Data Package Deliverables
14.4.2.1 Hardcopy Deliverables
Data deliverables for the fixed laboratories will consist of sample and QC results. At a
minimum, the data packages from the analytical chemistry laboratories will include the
following:
1. Case narrative
summary of analytical methods used
correlation of field sample identifications and laboratory sample identifications
data qualifier definitions
deviations from established QA/QC procedures with corrective action
2. Sample results
project name
L2005-346 Rev. 1
CITY_DEP_WORBY_CANNATA_SUBP_000114741
NYC-WTC_000428424