NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
completeness yield data that arc not usable, the Data Validation memoranda will
identify how this problem will be resolved.
16.2.6 Data Limitations and Actions
The field and laboratory data collected during this investigation will be used to
achieve the objectives identified in Section 8.0 of this QAPP. The QC results
associated with each analytical parameter will be compared to the objectives
presented in this QAPP. Data generated in association with QC results meeting the
stated acceptance criteria (i.e., data determined to be valid) will be considered usable
for decision-making purposes. Limitations on the use of the data will be stated and
explained, if necessary. In addition, the data obtained may be both qualitatively and
quantitatively assessed on a projectwide, location specific, and parameter-specific
basis. Results of the measurement error assessments may be applied against the site as
a whole; any conclusions will be documented in data validation or QA reports. Data
generated in association with QC results not meeting the stated acceptance criteria
may still be considered usable for decision-making purposes, depending on certain
factors. This assessment will be performed by the AIRTEK Project Manager, in
conjunction with the AIRTEK Project QA Officer. In general, qualified data will still
be usable for project objectives. Qualified data exhibiting concentrations close to the
project Action Levels will be evaluated further to determine if there is a potential bias
caused by the QC nonconformance which may have caused a false exceedance or a
false non-exceedance.
Eactors to be considered in this assessment of field and laboratory data will include,
but not necessarily be limited to, the following.
• Conformance to the field methodologies proposed in the QAPP,
• Conformance to the EPA and NIOSH methods provided in the QAPP,
• Adherence to proposed sampling strategy,
• Presence of elevated detection limits due to matrix interferences present in
background ambient air or contaminants present at high concentrations,
• Presence of analytes not expected to be present,
• Conformance to validation protocols included in the QAPP for both field and
laboratory data,
• Unusable data sets (qualified as “R”) based on the data validation results,
• Data sets identified as usable for limited purposes (qualified as “J”) based on
the data validation results,
• Effect of qualifiers applied as a result of data validation on the ability to
achieve the project objectives,
• Status of all issues requiring corrective action, as presented in the QA reports
to management,
• Effect of nonconformance (procedures or requirements) on project objectives,
• Adequacy of the data as a whole in meeting the project objectives,
• Identification of any remaining data gaps and need to reevaluate data needs.
102
CITY_DEP_WORBY_CANNATA_SUBP_0001 01753
NYC-WTC_000428001
OCR can misread numbers and units. Confirm readings against the page image before using them.