NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 11 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: August 2005 Lower Manhattan Development Corporation Page 70 of 116

11.2.2 Fixed Laboratory QC

All required QC checks and QC samples and the associated QC acceptance limits are detailed in the associated methods and in Tables 8-2 through 8-9.

11.2.2.1 Method Blanks/Preparation Blanks

Method blanks will be performed as part of each analytical batch for each methodology performed. Method blanks are used to evaluate contamination introduced during sample preparation and/or analysis by the laboratory.

11.2.2.2 Instrument Blanks

Instillment blanks are used to evaluate contamination resulting from the analytical reagents and the instrumentation. In addition, instrument blanks are sometimes used to assess potential carryover after the analysis of a highly contaminated sample. Instrument blanks are only required for select analytical parameters.

11.2.2.3 Surrogate Spikes

Surrogate spikes are used to evaluate extraction efficiency or analytical bias on a sample by sample basis for organic parameters. Surrogate spikes are added to all samples for organic parameters. Surrogate spikes are another measure of sample-specific QC.

11.2.2.4 Laboratory Control Samples'

Laboratory control samples (LCSs) and LCS Duplicates are used to evaluate almost all parameters for the ability of the laboratory to accurately and precisely identify and quantitate target compounds in a reference matrix when spiked at the mid range of the calibration curve at a known concentration using a secondary source standard. LCSs and/or LCS Duplicates are typically performed as part of each analytical batch for each methodology with the exception of asbestos, PMio and PM2.5.

11.2.2.5 Laboratory Duplicate

Laboratory duplicates are used to evaluate laboratory preparation and analysis precision. These analyses are typically performed for inorganic parameters only. Laboratory duplicates are typically performed at a frequency of one per twenty samples.

11.2.2.6 Internal Standards

Internal standards are used to assess the analytical accuracy, precision, and stability. Internal standards are typically only used for organic analyses and ICP/MS analyses. Internal standards are spiked into all samples and are considered a sample-specific QC measure.

L2005-346 Rev. 1

CITY_DEP_WORBY_CANNATA_SUBP_000093802

NYC-WTC_000427291

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427291Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000428324

Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

NYC-WTC_000449648

Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →